3.4 Installation of Built-In
Cooktops on a CYLINDER
COMPARTMENT
The opening of this compartment have to permit
the easy introduction and removal of the cylinder.
The dimension of the opening and the inside of
the compartment shall be at least large enough
to accommodate the cylinders (with regulator
fitted) which are the most commonly used in the
country. The total area of the opening in the upper
part shall be at least 1/100 of the floor area of the
compartment. The total area of the openings of
the base shall be at least 1/50 of the floor area of
the compartment. The cylinder support:
Shall have sufficient mechanical strength.
Shall not let the cylinder rest directly in the ground.
Shall not sill higher than the base on which the
cylinder rests.
The cylinder tap have to be readily accessible.
Overflow of liquid from pans of the hotplate shall
not fall onto cylinder or its accessories.
The flexible tube shall not be in contact with
sharp edges. No internal communication shall
exist between the cylinder compartment and the
different parts of the appliance where burners are
placed.
The ventilation openings of the compartment
cannot be obstructed when the appliance is
placed in position.
3.5 Gas Connection for
Cooktop
The cooktop should be connected to the
gas supply by an authorized installer. During
installation of this product it is essential to fit an
approved gas tap to isolate the supply from the
appliance for the convenience of any subsequent
removal or servicing. Connection of the appliance
to the gas mains or liquid gas tanks must be carried
out according to the safety standards currently
in force, and only after it is ascertained that it is
suitable for the type of gas to be used.
Built-In Hob / User Manual
If not, follow the instructions indicated in the
section entitled, "Adapting the cooktop for
Different Types of Gas". If the cooktop is to be
connected to tanks containing liquid gas, use
pressure regulators that comply with current
safety standards.
To insure that the appliance
operates safety, the gas is regulated
C
correctly and your appliance lasts
overtime, make sure that gas
pressure levels comply with the
indications given in Table 1, "Nozzle
and Burner Specifications".
3.6 Gas connection to Non-
flexible Pipe
(Copper or Steel)
Connection to the gas source must be done in such
a way as to not create any stress points at any part
of the appliance.
The appliance is fitted with an adjustable, "L"
shaped connector and a gasket for the attachment
to the gas supply. Should this connector have to be
turned he gasket must be replaced (supplied with
the appliance).
The gas feed connector to the appliance is a
threaded, male 1/2" connector for round gas pipe.
3.7 Gas Connection to Flexible
Steel Pipe
The gas feed connector to the appliance is a
threaded, male 1/2" connector for round gas pipe.
Only use pipes, tubes and gaskets that comply
with current safety codes. The maximum length
of the flexible pipes must not exceed 2000 mm.
Once the connection have been made, ensure that
the flexible metal tube does not touch any moving
parts and not crushed.

3.8 Check the Seal

Once the appliance have been installed, make sure
all the connections are properly sealed, using a
soapy water solution. Never use a flame.