Adjustment
GEOMETRIC ALIGNMENT:
Receive the monochrome circle pattern (NTSC system):
Check vertical center and horizontal center and H-linearity. If they are not standard,
press FACTORY button to enter service mode, and adjust vertical size, vertical
linearity, vertical center, horizontal center, make them standard.
Alignment parameter table:
Press FACTORY button on service remote controller and enter service mode:
1. Adjustment mode and
2. Setting mode;
CH+ or CH- button up/down pages to select items that you need adjust; use
VOL+ or VOL- button
C03 0094201111 Capacitor CD110-25V-4.7_F-M------F 1
C07 0094201111 Capacitor CD110-25V-4.7_F-M------F 1
C16 0094201111 Capacitor CD110-25V-4.7_F-M------F 1
C09 0094200640 Capacitor CD110-25V-10_F-M------F 1
C14 0094200640 Capacitor CD110-25V-10_F-M------F 1
C20 0094200640 Capacitor CD110-25V-10_F-M------F 1
C19 0094200581 Capacitor CD110X-25V-100_F-M------F 1
Q01 0094600119 Oscillator CSB503F58 1
XS611 0094300135 Connect housing TJC8-6A 1
XS612 0094300135 Connect housing TJC8-6A 1
N01 0094400796 IC TDA9850 1
16. Damageable Parts List
Location Material Code Parts Name Type Qt. (unit) Remark
T101 0094500340 Inducer's HA6019 1
A101 0094003734 Tuner ENV56DB4G3 1
N101 0094400457 IC LA76814K 1
V432 0094401590 Transistor 2SC5299-YB----B-A 1
N451 0094400305 IC LA7841 1
N701 0094401090 IC LC863232A-5V57 1
17. Information of Resistors and Capacitors
CAPACITORS
RESISTORS & CAPACITORS-PARTS NO.CODE
Notes: 1. Part numbers are indicated on most mechanical parts.
Please use this part number for parts orders.
2.The unit of resistance is (ohm). K=1000, M=1000K
3.The unit of capacitance is F (microfarad). 1pF=10-6 F.