Dynamix US-SE User Manual

G.shdsl.bis efm network extender
Table of Contents

Advertisement

Quick Links

 
 
 
 
Dynamix UM-SE
G.SHDSL.bis
EFM
Network Extender

User Manual

Version 0.03
 
 

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the US-SE and is the answer not in the manual?

Questions and answers

Summary of Contents for Dynamix US-SE

  • Page 1: User Manual

            Dynamix UM-SE G.SHDSL.bis Network Extender User Manual Version 0.03    ...
  • Page 2: Table Of Contents

      3.5.1.5 SNR margin ..........................25     3.5.1.6 Line Probe..........................26     3.5.2 VLAN ..........................27     3.5.2.1 802.1Q Tag‐Based VLAN......................29     3.5.2.2 Port‐Based VLAN........................32     3.5.2.3 Port‐based QinQ ........................34 Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 3 Annex ............................71     4.4.1.4 TCPAM ............................71     4.4.1.5 Maximum main rate ........................71     4.4.1.6 SNR Margin..........................71     4.4.1.7 Line Probe..........................71     4.4.1.8 Clear ............................71 Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 4 Trap host............................ 95     4.10.4 Supervisor Password and ID ...................96     4.10.4.1 Supervisor Password........................96     4.10.4.2 Supervisor ID ..........................96     4.11 .............................97 TILITY     4.11.1 Upgrade main software ....................98     4.11.2 Backup system configuration..................98 Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 5     4.11.3 Restore system configuration ..................98     4.12 EXIT ............................99     APPENDIX – SETUP TABLE ........................100 Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 6: Introduction

    (QoS) requirements by utilizing 802.1q VLAN capabilities, four levels of priorities, traffic flow control and rate control. This traffic management and QoS features enable service providers to offer highly profitable and value-added services to a vast majority of business and institutional sites. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 7: Features

    Up to 2K MAC Address Indicators WAN1, WAN2, WAN3 and WAN4: Link/Activity LAN1, LAN2, LAN3 and LAN4: Link/Act and 10M/100Mbps System: Power, Alarm and Management port VLAN Support 802.1Q Tag-Based VLAN Port-Based VLAN Port-Based Q-in-Q Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 8 Humidity: 0%~95%RH (non-condensing) Memory 2MB Flash Memory, 8MB SDRAM Products’ Information Dynamix UM-SE/1 pair 2BASE-TL EFM Network Extender Dynamix UM-SE/2 pair 2BASE-TL EFM Network Extender Dynamix UM-SE/4 pair 2BASE-TL EFM Network Extender Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 9: Applications

    Applications EFM DSLAM to point connection Point to point connection Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 10: 2 Getting To Know About The Efm Modem

    2 Getting to know about the EFM Modem This section will introduce hardware of the EFM modem. Front Panel The front panel contains LED which show status of the EFM Modem. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 11: Lan

    LAN 2 is on 10M mode LAN 3 is on 100M mode 100M 3 LAN 3 is on 10M mode LAN 4 is on 100M mode 100M 4 LAN 4 is on 10M mode Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 12: Rear Panel

    For one pair (2-wire) model, Loop1 has been used For two pair (4-wire) model, Loop1 and 2 have been used For four pair (8-wire) model, Loop1, 2, 3 and 4 have been used Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 13: Lan Ports And Mgmt Port

    The pin assignment of RJ-45 modular jack on the console cable: Pin Number Abbrev. Description Figure DCE ready Received Line Signal Detector DTE ready Signal Ground Received Data Front View Transmitted Data Clear to Send Top View Request to Send Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 14: Power Connection

    The function of protective earth does not serve the purpose of providing protection against electrical shock, but instead enhances surge suppression on the DSL lines for installations where suitable bonding facilities exist. The connector type is M3 machine screw. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 15: 3 Configuration Use Web Browser

    “admin” for username and “admin” for password. All display screen are as same as serial console configuration. The IP address 192.168.1.1 is the default vaule and you can change to another one for you application. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 16: Installation

    Turn on the PC or NB, which is used for configuration the EFM modem. To avoid possible damage to this EFM modem, do not turn on the EFM modem before Hardware Installation. Connection with SHDSL .Bis EFM Modem Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 17: Setup Up On Web Browser

    Note: After changing the User Name and Password, strongly recommend you to save them because another time when you login, the User Name and Password have to be used the new one you changed. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 18: Basic Setup

    Following is the first screen that displays when you access the web configurator. Basic Setup The Basic Setup contains: Operation mode and MGMT port IP DHCP server User can use it to completely basic setup the EFM modem. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 19 Below diagram is showed as Basic Setup’s flowchart. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 20: Operation Mode And Mgmt

    Internet service has been configured with a host name. In most cases, this field can be ignored. And than click Trigger DHCP service is Disable or Server. If you don’t need the DHCP service, please click Disable. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 21: Dhcp Server

    IP address when a computer is plugged into a different place in the network. The embedded DHCP server assigns network configuration information at most 253 users accessing the Internet in the same time. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 22 Moreover, you may assign a fixed IP address to some device while using DHCP, you have to put this device’s MAC address in the Table of Fixed DHCP Host Entries. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 23: Lan

    You must type the dotted decimal notation for DNS Server’s IP address The default values are as following: IP Address: 192.168.2.1 Subnet Mask: 255.255.255.0 Gateway: 0.0.0.0 DNS Server 1: 168.95.1.1 DNS Server 2: 168.95.192.1 DNS Server 3: Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 24: Review

    The screen will prompt the new configured parameters. Checking the parameters and Click Restart The EFM modem will reboot and working with new parameters or press or Continue to configure another parameters. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 25: Advanced Setup

    Advanced setup contains SHDSL.bis EFM, VLAN, QoS and Rate Control parameters. 3.5.1 SHDSL.bis EFM You can setup the Link (number of wires), Annex type, TCPAM type, Main Rate, Sub Rate and SNR margin for SHDSL.bis EFM parameters. Click SHDSL.bis EFM Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 26: Line Type

    SNR margin SNR margin is an index of line connection quality. You can see the actual SNR margin in STATUS SHDSL.bis. The larger is SNR margin; the better is line connection quality. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 27: Line Probe

    The screen will prompt the parameters that will be written in NVRAM. Check the parameters before writing in NVRAM. Press Restart to restart the EFM modem working with new parameters or press continue to setup another parameter. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 28: Vlan

    Port Based VLAN type in this screen. The IEEE 802.1Q defines the operation of VLAN bridges that permit the definition, operation, and administration of VLAN topologies within a bridged LAN infrastructure. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 29 Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 30: Q Tag-Based Vlan

    PVID: (Port VID) It is an untagged member from 1 to 4094 of default VLAN. Link Type: Access means the port can receive or send untagged packets. Trunk means that the prot can receive or send tagged packets. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 31 Before enabling VLANs for the EFM modem, you must first assign each port to the VLAN group(s) in which it will participate. By default all ports are assigned to VLAN1 as untagged Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 32 Link Type - Sets the port to accept the frame types: “Access” means the port can only receive or send untagged frame types. “Trunk” means that the prot can only receive or send tagged frame types. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 33: Port-Based Vlan

    As with other VLAN approaches, the packets forwarded using this method do not leak into other VLAN domains on the network. After a port has been assigned to a VLAN, the port cannot send to or receive from devices in another VLAN. For example, Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 34 If you click the LAN1 to LAN4 only with DSL and Sniffing, there are port isolation means that each LANs port can only communicate with management port and cannot communicate with each other. This option is the most limiting but also the most secure. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 35: Port-Based Qinq

    A VLAN tag uses the tag protocol identifier (TPID) field to identify the protocol type of the tag. The value of this field, as defined in IEEE 802.1Q, is 0x8100 (33024). VLAN Tag structure of an Ethernet frame Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 36 TPID value to any of the values in the table below. Reserved protocol type values: Protocol type Value 0x0806 0x0200 RARP 0x8035 0x0800 IPv6 0x86DD PPPoE 0x8863/0x8864 MPLS 0x8847/0x8848 IPX/SPX 0x8137 IS-IS 0x8000 LACP 0x8809 802.1x 0x888E Cluster 0x88A7 Reserved 0xFFFD/0xFFFE/0xFFFF Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 37: Qos

    The priority modes have three types: Port Based Priority, VLAN Tag Priority and IP DSCP Priority. You can also set Disable the QoS function. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 38: Port Based Priority

    Q1 and so on. If higher priority queues never empty, then traffic on lower priority never gets sent. The SP class is typically for video applications that require a fixed amount of bandwidth to be considered good quality. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 39 This works in a looping fashion until a queue is empty. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 40: Vlan Tag Priority

    VLAN membership information. IEEE 802.1Q Tagged Frame for Ethernet: User priority is giving eight ( 2 = 8 ) priority levels. The default value is 0, indicating normal treatment. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 41 Type 1 Weight Set up the Weighted Round-Robin (Type 1) shares bandwidth by using scheduling weights 1, 2, 4 and 8 for queues 0 through 3 respectively. VLAN Tag Priority: Priority Queue Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 42 According to above two tables, we can get the mapping QoS values to Egress Queues as the following: Queue Priority Queue 0 Queue 1 Queue 2 Queue 3 Serviced by weighted round robin (WRR) Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 43: Ip Dscp Priority

    DiffServ network. Based on the marking rule different kinds of traffic can be marked for different priorities of forwarding. Resources can then be allocated according to the DSCP values and the configured policies. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 44 Medium Drop AF12 AF22 AF32 AF42 DSCP 12 DSCP 20 DSCP 28 DSCP 36 001110 010110 011110 100110 High Drop AF13 AF23 AF33 AF43 DSCP 14 DSCP 22 DSCP 30 DSCP 38 Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 45 When click finish, there will have a QoS parameters review page for your confirm. To let the configuration that you have changed take effect, click Restart to reboot system. If you want to continue the setup procedure, click Continue is O.K. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 46: Rate Control

    You can setup the date rates limit on each port. The date rates are: No limit, 128K, 256K, 512K, 1M and 2M. The default setting is No limit on each ports. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 47: Status

    4-pairs model (8 wire model)will showed as following, you can know about their four channel run-time status( from channel A to D). Below display screen is come from four pair model(8 wire model): Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 48 Note: CPE side’s line rate according to the setting of CO side. If you want to clear the performance data on ERC Error Count, click Clear CRC Error is O.K. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 49: Mgmt

    3.6.2 MGMT MGMT status will display the MGMT interface information. You can view the general status of MGMT interface and DHCP client table. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 50: Lan

    3.6.3 LAN status will prompt the setting on IP type, IP address and Subnet mask. For example,It shows the IP type of LAN interface is Fixed: Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 51: Interface

    The field shows the number of transmitted packets on this port InDiscards The field shows the discarded number of received packets on this port OutDiscards The field shows the discarded number of transmitted packets on this port Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 52: Administration

    EFM modem and change the parameters. Press Security to setup the parameters. For better security, change the Supervisor ID and Supervisor password for the EFM modem. If Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 53 Can only use ping test, view the status and configuration Exit Web Brower mode: Supervisor ID Supervisor Password All function can use Logout There have a Telnet Port number setting. The default value is 23. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 54 The browser will prompt the configured parameters and check it before writing into NVRAM. Press Restart to restart the EFM modem working with the new parameters and press Continue to setup other parameters. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 55: Snmp

    The EFM modem can generate SNMP traps to indicate alarm conditions, and it relies on SNMP community strings to implement SNMP security. This EFM modem support both MIB I and MIB II. Click SNMP to configure the parameters. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 56: Community Pool

    In the table of current trap host pool, you can setup the trap host. SNMP trap is an informational message sent from an SNMP agent to a manager. It is a management station (SNMP application) that receives traps. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 57 The browser will prompt the configured parameters and check it before writing into NVRAM. Press Restart to restart the EFM modem working with the new parameters and press Continue to setup other parameters. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 58: Utility

    This section will describe the UTILITY of the EFM modem. The UTILITY menu including: SYSTEM INFO: system information, CONFIG TOOL: load the factory default configuration, UPGRADE: upgrade the firmware LOGOUT: logout the system RESTART: restart the EFM modem. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 59: System Info

    You can check the MCSV, Software Version, Chipset, Firmware Version, Host Name and System Up Time. The System Up Time item let you know the EFM modem how long time after power on. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 60: Config Tool

    After configuration, suggest using the function to backup your EFM modem parameters in the PC. Select the Backup Configuration and then press Finish. Browse the place of backup file named backup. Press Finish. The EFM modem will automatically backup the configuration. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 61: Upgrade

    To exit the web configurator, press LOGOUT. You have to log in with your password again after you log out. This is recommended after you finish a management session for security reasons. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 62: Restart

    3.8.5 Restart For restarting the EFM modem, press Restart to reboot the EFM modem. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 63 When you press Restart, display screen is as following: It show the configuration is success. When the system have rebooted later, you can re-open the browser. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 64: Configuration Use Serial Console And Telnet With Menu Driven Interface

    Input User and Password after login screen pop up. The system asks for User and Password, please enter “admin” both for the factory default password. As show in the following: Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 65: Menu Driven Interface Commands

    It can show you all of available commands for you to select. You don’t need to remember the command syntax and save your time on typing the whole command line. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 66: Window Structure

    The main menu tree is as following figures. All of the configuration commands are placed in the subdirectories of Enable protected by supervisor password. Unauthorized user cannot change any configurations but can view the status and configuration of the EFM Modem and Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 67: Menu Tree For Authorized User

    EFM modem is working. 4.2.1 Menu tree for authorized user If you are the authorized user, the menu tree is the following: Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 68: Menu Tree For Unauthorized User

    If you are the unauthorized user, the menu tree is the following: If you are the unauthorized user, you can view the display screen as below. Only have view status, show system and ping function. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 69: Enable

    Show running system status show View system configuration write Update flash configuration reboot Reset and boot system ping Packet internet groper command admin Setup management features utility TFTP upgrade utility exit Quit system Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 70 “reboot” command, or all of your changes will not take effect. ping Internet Ping command. admin You can setup management features in this command. utility Upgrade software and backup and restore configuration are working via “utility” command. exit Quit system Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 71: Setup

    2-wire mode. 8-wire product can be worked under 4-wire mode and 2-wire mode. Link type 2-wire 4-wire 8-wire EFM modem ● 2-wire model ● ● 4-wire model ● ● ● 8-wire model Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 72: Annex

    For adaptive mode, you can setup the Line Probe is Enable. The EFM modem will adapt the data rate according to the line status. Otherwise, setup to Disbale. 4.4.1.8 Clear The Clear command can clear CRC error count. SHDSL.bis: Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 73 □STU-C □STU-R Mode □2-wire □4-wire □8-wire Link Type □AF □BG Annex Type □Auto □TCPAM-16 □TCPAM-32 TCPAM Max Main Rate (3~89) SNR Margin (-10~21) □Disable □Enable Line Probe Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 74 Subnet mask (ENTER for default) <255.255.255.0>: ----------------------------------------------------------------------------- You can configure LAN IP address, subnet mask. The default value is 192.168.2.1 and 255.255.255.0 LAN: □Disable □Dynamic □Static Link Type IP Address Subnet mask Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 75: Vlan

    VLAN, set to Disable. ----------------------------------------------------------------------------- Command: setup vlan mode <Disable|8021Q|Port> Message: Please input the following information. Trigger VLAN function (TAB Select) <Disable>: ----------------------------------------------------------------------------- VLAN Mode: □Disable □802.1Q Tag VLAN □Port Based VLAN VLAN Mode Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 76: Q Vlan

    5 represents DSL and index 6 represents Sniffing respectively. ----------------------------------------------------------------------------- Command: setup vlan link_mode <1~6> <Access|Trunk> Message: Please input the following information. Port index <1~6>: 1 Port link type (TAB Select) <Access>: ----------------------------------------------------------------------------- Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 77: Port Based Vlan

    For Port Based VLAN, user must set up the table using 802.11Q methods. But don’t care the value of VID , PVID or link type. Port Based VLAN: LAN1 LAN2 LAN3 LAN4 Sniffing Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 78 Use List command can show the setup table for you check: ----------------------------------------------------------------------------- Virtual LAN Parameter VLAN Mode : Port-Based VLAN Virtual LAN Table No LAN1 LAN2 LAN3 LAN4 DSL Sniffing ---- ---- ---- ---- ---- -------- ----------------------------------------------------------------------------- Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 79: Qos

    For example, the default values are as following [ setup qos qweight 0 1] [ setup qos qweight 1 2] [ setup qos qweight 2 4] [ setup qos qweight 3 8] Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 80: Queue Weight

    This works in a looping fashion until a queue is empty. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 81: Port Based Priority Qos

    Queue index (ENTER for default) <3>: 3 ----------------------------------------------------------------------------- Set up queue value (0, 1, 2 or 3) on each ports. Port Based Priority QoS: Port 1(LAN1) 2(LAN2) 3(LAN3) 4(LAN4) 5(DSL) 6(Sniffing) Queue Index Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 82: Vlan Tag Priority Qos

    WRR uses a predefined relative weight for each queue that determines the percentage of service time to services each queue before moving on to the next queue. VLAN Tag Priority QoS: VLAN Tag Index Queue Index Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 83: Ip Dscp Priority Qos

    Queue index (ENTER for default) <0>: ----------------------------------------------------------------------------- IP DSCP QoS: Queue Queue Queue Queue DSCP DSCP DSCP DSCP Index Index Index Index 4.4.4.7 List This command can show the setup table for you check. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 84: Rate

    1. The default IP address and subnet mask are 196.168.1.1 and 255.255.255.0 . >> address MGMT IP address and subnet mask ---------------------------------------------------------------------- Command: setup mgmt 1 address <ip> <netmask> Message: Please input the following information. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 85: Dhcp

    IP address when a computer is plugged into a different place in the network. To configure DHCP server, move the cursor to dhcp and press enter. >> generic DHCP server generic parameters fixed DHCP server fixed host IP list Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 86: Dhcp Fixed Host

    >> add Add a fixed host entry delete Delete a fixed host entry When use the fixed host entry, you must enter the MAC address and IP address as the same Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 87: Dns Proxy

    Internet service has been configured with a host name. In most cases, this field can be ignored. Enter local host name via hostname command. Move cursor “ >> “ to hostname and press enter. ---------------------------------------------------------------------- Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 88: Default

    CRC error count of remote side modem. The modem can access remote side information via EOC (embedded operation channel). interface The statistic status of MGMT interface can be monitor by interface command. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 89 The SHDSL.bis status includes mode, line rate, SNR margin, attenuation, and CRC error count of the local side modem, and SNR margin, attenuation and CRC error count of remote side modem. 4.5.2 Interface Move cursor “ >> “ to interface and press enter. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 90: Show

    For any changes of configuration, you must write the new configuration to flash component using write command and then reboot the EFM modem to take affect. Move cursor “ >> “ to write and press enter. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 91: Reboot

    Default: It will send 4 packets only 1~65534: Set the number of ping request packets from 1 to 65534 -t : It will continuous until you key Ctrl+C to stop Data Size: From 1 to 1999 Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 92: 4.10 Administration

    >> attrib UI mode profile User name and password Move the cursor “>>” to attrib and press enter. ----------------------------------------------------------------------------- Command: admin user modify 2 attrib <Command|Menu> Message: Please input the following information. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 93: Security

    Legal address IP address pool list Show security profile 4.10.2.1 Telnet TCP port User can set up the telnet TCP port from 1 to 65534. The default port is 23. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 94: Ip Address Pool

    Telnet TCP port and 16 host IP address listing for your confirmation. Telnet TCP Port: Telnet TCP Port Legal client IP Address pool: Legal client IP Address pool Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 95: Snmp

    You can setup the following: Validate: Set Enable or Disable. Community: Key in the string which is serves as password for access right. Access right: Set Read only, Read Write or Denied Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 96: Trap Host

    Trap host IP address: Type the trap host IP address Community: Type the community password (string) Move the cursor to list and press enter, you can view full listing on SNMP Trap Host Pool. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 97: Supervisor Password And Id

    Command: admin id <name> Message: Please input the following information. Legal user name (ENTER for default) <root>: ----------------------------------------------------------------------------- The default legal user name is root. Supervisor ID and Password: Supervisor ID Supervisor Password Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 98: 4.11 Utility

    Move the cursor “ >> “ to utility and press enter. >> upgrade Upgrade main software backup Backup system configuration restore Restore system configuration Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 99 Message: Please input the following information. TFTP server IP address (ENTER for default) <192.168.0.2>: Upgrade filename (ENTER for default) <default.bin>: ----------------------------------------------------------------------------- Type TFTP server IP address and restore filename of system configuration. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 100 Please press “y”, you can quit this system. The screen will display: ------------------------------------------------------------------ Connection closed... Press SPACE key to enter console mode configuration! ------------------------------------------------------------------ You can press SPACE key to enter this system again. Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 101 □No limit      □128K      □256K      □512K      □1M      □2M    Port 5  DSL  Port 6  Sniffing  □No limit      □128K      □256K      □512K      □1M      □2M    Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 102       5              6              7              8              Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 103   28    44    60    13    29    45    61    14    30    46    62    15    31    47    63    Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 104 6    7    8    9    10    11    12    13    14    15    16      Supervisor ID and Password:    Supervisor ID  Supervisor Password      Host Name:  Host Name  Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...
  • Page 105 Trap Host entry    (4)    □Disable    □Ver.1      □Ver.2  Version  IP Address    Community      Trap Host entry    (5)    □Disable    □Ver.1      □Ver.2  Version  IP Address    Community      Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003...

Table of Contents