3-1. Gun Recommendation Table

Process
GMAW − Hard or Corded Wires
FCAW − Self-Shielding Wires

3-2. Equipment Connection Diagrams

1

3-3. 14-Pin Plug Information

J
J
A
A
K
K
I
I
B
N
N
L
L
C
C
H
H
M
M
D
D
G
G
E
F
*The remaining pins are not used.

3-4. Specifications

Type of Input
Welding Power
Power
Source Type
24 Volts AC Single
Constant Voltage
Phase
(CV) DC with 14
5 Amperes 50/60
pin and Contactor
Hz
Control
SECTION 3 − INSTALLATION
Gun
M25 Or M40
GA-40GL
2
Pin*
A
24 volts ac with respect to pin G.
B
Contact closure to A completes 24 volts ac contactor control circuit.
G
Circuit common for 24 volts AC circuit.
C
+10 volts dc output to remote control with respect to pin D.
D
Remote control circuit common.
E
0 to +10 volts dc input command signal from remote control with respect to pin D.
H
Voltage feedback; 0 to 10 volts dc, 1 V/10 arc volts
Wire Feed
Diameter
Speed Range
0.6 to 2.0 mm
(0.23 to 5/64 in)
0 to 20 mpm
(0 to 788 ipm)
Max Spool Weight:
15 kg (33.0 lb.)
Pin Information
Wire
Welding
Circuit Rating
Range
100 Volts,
500 Amperes,
100%
Duty Cycle
1
CV Welding Power Source with
14 pin Amphenol Receptacle
2
Interconnecting Control Cord
(Required)
3
Weld Cable (Required)
4
Work
4
3
Ref. S-0004-A
Overall
Weight
Dimensions
Length: 650 mm
ST 44 Series &
(25.5 in)
ST Blu Fab
Width: 220 mm
(22.0 kg (48 lbs)
(8.65 in)
ST 44 Ultra-Lite
Height: 420 mm
15.0 kg (33 lbs)
(16.5 in)