Stove Clearances - Jøtul F 3 C Installation And Operating Instructions Manual

Table of Contents

Advertisement

USA/Canada
Jøtul F 3 Clearances

Stove Clearances

Top vent/vertical
Rear heatshield with
Single wall pipe
Rear heatshield with
Double wall pipe or shields
Stove Clearances
Rear Vent/Horizontal
Rear heatshield with
Single wall pipe
Rear heatshield with
Double wall pipe or shields
f i r e - p a r t s . c o m
Connector
Clearances
Singlewall pipe -vertical installations
Double wall pipe-vertical installations
Single wall pipe -horizontal installations
Double wall pipe-horizontal installations
Dimensions in Inches represent U.S. requirements.
Dimensions in Millimeters represent Canadian requirements.
Wall protection is discussed in further detail on page
10 of this manual.
12
Unprotected Surfaces
Side
Rear
Corner
24"
25"
18"
610mm 635mm 460mm
18"
10"
14"
460mm 255mm 355mm
Unprotected Surfaces
Side
Rear
Corner
24"
25"
20"
610mm 635mm 510mm
18"
14"
17"
460mm 355mm 430mm
Unprotected Surface
18" (460mm)
pipe mfgr. listing
18" (460mm)
pipe mfgr. listing
Protected Surfaces
per NFPA 211 or CAN/CSA-B365-M
Side
Rear
10"
14"
255mm 355mm
6"
6"
150mm 150mm
Protected Surfaces
per NFPA 211 or CAN/CSA-B365-M
Side
Rear
10"
25"
255mm 635mm
6"
6"
150mm 150mm
Protected Surface
per NFPA 211 or CAN/CSA-B365-M
6" (150mm)
pipe mfgr. listing
9" (230mm)
pipe mfgr. listing
A
C
D
A: Top to Mantel
B: Top to Top Trim
C: Side to Side trim
D: Side to Side Wall 24"
Maximum Mantel Depth:
Maximum Top and Side Trim Depth: 1 1/2" 38 mm
Corner
10"
255mm
6"
150mm
Corner
18"
460mm
6"
150mm
B
34"
860 mm
20"
510 mm
13"
330 mm
610 mm
11 1/2" 292 mm

Advertisement

Table of Contents
loading

Table of Contents