Installation
Suggestion for installation
•
The compressor used to drive the tool must be able to maintain a working
pressure of at least 4 bar for the tool to work properly.
•
Use quick-couplings to easily disconnect the tool and hose from the compressor.
•
Make sure that the connected tool and hoses do not have a lower capacity than
the compressor and that they are correctly fitted.
•
If a pressure regulator is used it must be able to b set for a working pressure
of 4–7 bar.
Lubrication
Note! Lubricate with a few drops of the oil provided to the air fitting before
the tool is used for the first time.
1. Disconnect the compressed air from the nail gun.
2. Put 4–5 drops of the oil provided in the air inlet.
Note! Do not use ordinary motor oil. As it contains additives that will damage the
tool. Oil for lubricating a pneumatic tool is available commercially.
3. Wipe away any oil that may come out of the air inlet when beginning to
use the tool.