3-14. Selecting Input Voltage (200/230/460 Volt Models Only)

2
Tools Needed:
5/16 in
OM-1327 Page 20
.
A complete Parts List is available at www.MillerWelds.com
.
Be sure to reinstall all four screws
securing relinking board in place.
3
4
3
5
!
.
1
.
1
Check voltage selected in unit.
Changing selection is only neces-
sary if selected value does not
match available input voltage.
2
3
4
5
Move relinking board as needed
and connect plug PLG32 (in unit) to
RC23 or RC46 according to input
power voltage.
Turn Off welding power
source, disconnect input
power, and check voltage on
input capacitors according
to
Section
6-3
before
proceeding.
Check input voltage available
at site.
Incorrect linking can damage
unit and void the warranty.
Voltage Selection View
Window
Relinking Board PC6
Mounting Screws
Receptacle RC23
(Connection For 230 VAC
Input Power)
Receptacle RC46
(Connection For 460 VAC
Input Power)