SECTION 8 − SELECTING AND PREPARING
NOTE

8-1. Selecting Tungsten Electrode

Electrode Diameter
Negative/Straight Polarity
Pure Tungsten
(Green Band)
.010"
.020"
.040"
1/16"
3/32"
1/8"
5/32"
3/16"
1/4"
2% Thorium Alloyed
Tungsten (Red Band)
.010"
.020"
.040"
1/16"
3/32"
1/8"
5/32"
3/16"
1/4"
Zirconium Alloyed Tung-
sten (Brown Band)
.010"
.020"
.040"
1/16"
3/32"
1/8"
5/32"
3/16"
1/4"
Typical argon shielding gas flow rates are 15 to 35 cfh (cubic feet per hour).
*Not Recommended.
The figures listed are intended as a guide and are a composite of recommendations from American Welding Society (AWS) and electrode
manufacturers.
OM-218 Page 28

TUNGSTEN ELECTRODE

For additional information, see your distributor for a handbook on the Gas
Tungsten Arc Welding (GTAW) process.Wear clean gloves to prevent
contamination of tungsten electrode.
DC − Argon − Electrode
DC − Argon − Electrode
Positive/Reverse Polarity
Up to 15
5-20
15-80
70-150
125-225
225-360
360-450
450-720
720-950
Up to 25
15-40
25-85
50-160
135-235
250-400
400-500
500-750
750-1000
*
*
*
*
*
*
*
*
*
Amperage Range - Gas Type
AC − Argon − Using
High Frequency
*
*
*
10-20
15-30
25-40
40-55
55-80
80-125
*
*
*
10-20
15-30
25-40
40-55
55-80
80-125
*
*
*
*
*
*
*
*
*
- Polarity
AC − Argon − Balanced
Wave Using High Freq.
Up to 15
Up to 10
5-20
10-20
10-60
20-30
50-100
30-80
100-160
60-130
150-210
100-180
200-275
160-240
250-350
190-300
325-450
250-400
Up to 20
Up to 15
15-35
5-20
20-80
20-60
50-150
60-120
130-250
100-180
225-360
160-250
300-450
200-320
400-500
290-390
600-800
340-525
Up to 20
Up to 15
15-35
5-20
20-80
20-60
50-150
60-120
130-250
100-180
225-360
160-250
300-450
200-320
400-550
290-390
600-800
340-525
gtaw 7/97

Hide quick links: