Selecting And Preparing Weld Output Cables; Weld Cable Sizes - Miller Electric SRH-503 Owner's Manual

Arc welding power source
Table of Contents

Advertisement

4-7. Selecting And Preparing Weld Output Cables

Tools Needed:

4-8. Weld Cable Sizes

100 ft (30 m) Or Less
Welding
10 To 60%
Amperes
Duty Cycle
100
4
150
3
200
3
250
2
300
1
350
1/0
400
1/0
500
2/0
600
3/0
*Weld cable size (AWG) is based on either a 4 volts or less drop or a current density of at least 300 circular mils per ampere. Contact your distributor for
2
the mm
equivalent weld cable sizes.
OM-2236 Page 14
1
2
10 ft (3 m)
3
10 ft (3 m)
2
Total Cable (Copper) Length In Weld Circuit Not Exceeding
150 ft
(45 m)
60 Thru 100%
Duty Cycle
4
4
3
2
2
1
1
1/0
1/0
2/0
2/0
3/0
2/0
3/0
3/0
4/0
4/0
2-2/0
4
For Example,
Total Cable
Length In Weld
Circuit = 20 ft (6 m)
200 ft
250 ft
(60 m)
(70 m)
10 Thru 100% Duty Cycle
3
2
1
1/0
1/0
2/0
2/0
3/0
3/0
4/0
4/0
2-2/0
4/0
2-2/0
2-2/0
2-3/0
2-3/0
2-4/0
1
Weld Output Cable
Determine total cable length in weld
circuit and maximum welding am-
peres. See Section 4-8 to select
proper cable size.
Use shortest cables possible.
Do not use damaged cables.
2
Terminal Lug
Use lugs of proper amperage
capacity and hole size for connect-
ing to work clamp, electrode holder,
and weld output terminals.
3
Insulated Electrode Holder
Install according to manufacturer's
instructions.
4
Work Clamp
Install onto work cable.
sb6.1 11/92 − S-0653
300 ft
350 ft
400 ft
(90 m)
(105 m)
(120 m)
1
1/0
2/0
3/0
3/0
4/0
4/0
2-2/0
2-2/0
2-3/0
2-3/0
2-3/0
2-3/0
2-4/0
2-4/0
3-3/0
3-3/0
3-4/0
1/0
3/0
4/0
2-2/0
2-3/0
2-4/0
2-4/0
3-3/0
3-4/0
S-0007-E