Connecting To Power Source; Input 14 Pin Information For Receptacle Rc1 - Miller Electric IH Owner's Manual

Single induction heating power source temperature control/recorder
Table of Contents

Advertisement

4-3. Connecting To Power Source

3

4-4. Input 14 Pin Information For Receptacle RC1

REMOTE 14
Remote Contactor
Remote Contactor
Remote Output Control
Remote Output Control
Power Source Fault
Remote Metering*
Remote Metering*
*See power source Owner's Manual for scaling information.
5
J
A
K
B
I
C
H N L
G M
D
E
F
1
6
2
Pin
A
+24 volts dc from power source.
B
Contact closure to A completes power source +24 volts dc contactor control circuit.
D
Control circuit common.
E
0 to +10 volts dc signal for power source output control.
F, J
Absence of contact closure from power source indicates power source output failure.
I
Actual frequency input signal.
L
Average power input signal.
M
Voltage input signal RMS.
N
Current input signal RMS.
4
sb7.1* 3/93 - Ref. S-0004-A / S-0750 / Ref. 802 926 / Ref. 801 049 / 801 825-B / Ref. 803 004-A
Pin Information
Turn Off power source.
1. IH/TS
2. Interconnecting Cord
3. 14-Socket Plug
4. 14-Pin Plug
Obtain cord with 14-socket plug on
one end and 14-pin plug on other
end.
5. Keyway
6. Remote 14 Receptacle RC1
(See Section 4-4)
To connect cord to a receptacle,
align keyway, insert plug, and
tighten threaded collar.
To connect remaining end of cord to
power source, align keyway, insert
plug, and tighten threaded collar.
OM-203 185 Page 9