7-2.
Diagnostics (Continued)
WELD
MOTR
WAIT
COM
Indicates a weld
Indicates a motor
cycle wait error.
communication error.
OVER
REL
AVG
TRIG
Indicates an over
Indicates a contactor
average current error.
on error.
WELD WAIT
The weld wait error indicates unit was not
ready for a weld sequence. Press Jog/
Purge button to clear error.
MOTR COM
The motor communication error indi-
cates motor board lost data communica-
tions. Press Jog/Purge button to clear error.
If condition persists, contact nearest factory
authorized service agent.
PLS WAIT
The uim communication error indicates
user
interface
board
communications. Press Jog/Purge button
to clear error. If condition persists, contact
nearest factory authorized service agent.
LOW WFS
The low wire feed speed error indicates
actual wire feed speed is lower than wire
feed
speed
command.
obstructions in the wire feed system or a
faulty wire drive system. Press Jog/Purge
button to clear error.
OM-201 540 Page 36
PLS
WAIT
Indicates a UIM
communication error.
TRIG
STUK
Indicates a trigger
closed error.
E STOP
The emergency stop error occurs if the
user presses an emergency stop button.
Reset the emergency stop button and press
Jog/Purge button to clear error. Only applies
to units equipped with E stop option.
RMD DONE
The RMD done message indicates the
RMD demo is completed. Pressing
Jog/Purge button will change the screen to
CYCL PWR on the display. Turn unit power
off and back on again.
OVER AVG
The over average error indicates that
current is outside the average range for the
set program parameters. Check and correct
lost
data
program parameters. Press Jog/Purge
button to clear error.
REL TRIG
The release trigger error indicates the
user held the gun trigger after an E stop was
reset causing the contactor to remain on.
Press Jog/Purge button to clear error.
TRIG STUK
Check
for
The trigger stuck error indicates the user
held the gun trigger during power up.
Release trigger and turn power off and back
on.
LOW
E
WFS
STOP
Indicates an
Indicates a low WFS
emergency stop error.
command error.
ERR
OVER
UNKN
CRNT
Indicates an
Indicates an
unknown error.
overcurrent error.
ERR UNKN
The unknown error indicates an error was
sent from the PCM board to the UIM, but
error condition is unknown. Make sure
welding power source is isolated from the
welding fixture. Press Jog/Purge button to
clear error.
OVER CRNT
The over current error indicates welding
power source primary current of the inverter
is too high. Turn welding power source off
and disconnect unit for servicing.
Attempting to reset the display to
continue welding may further damage
internal
prepower check of the unit is needed
including resistance measurements of R1
and R8 resistors on welding power source
Interconnect board. Resistors should
measure 30K ohms. Visually inspect
electrolytic capacitors C1 and C2 for any
possible damage. In the event of an over
voltage condition, R1 and R8 could open
potentially causing an imbalance in the
power circuit. This condition would create
excessive current in the inverter primary
transformer and result in the OVER CRNT
error.
RMD
DONE
Indicates RMD
demo is done.
components.