SECTION 6 – SETTING SEQUENCE PARAMETERS

6-1. Sequence Parameters In A Program

1. Preflow
2. Run-In
3. Start
4. Weld
5. Crater
6. Burnback
7. Postflow
X = Setting available.
Preflow
Time
Run-In
Preflow
Trigger
Pressed
Sequence
Volts
X
X
X
X
Weld Time
Start
Time
Weld
Start
Parameters
IPM
Seconds
0-9.9
X
X
0.00-5.00
X
0-100.0
X
0-5.00
0-0.25
0-9.9
Crater
Time
Burnback
Crater
Trigger
Released
If time is set to zero in Weld
sequence, welding continues until
gun trigger is released.
If time is set to zero in any timed
sequence
except
Weld,
sequence is skipped.
Burnback
Time
Postflow
Time
Time
Sequence
Postflow
End
OM-1500-1 Page 25