5-1. Installing Welding Generator
Movement
Location
5-2. Grounding Generator To Truck Or Trailer Frame
Electrically bond generator frame
to vehicle frame by metal-to-metal
contact.
Y Bed liners, shipping skids, and some running
gear insulate the welding generator from the ve-
hicle frame. Always connect a ground wire from
the generator equipment grounding terminal to
bare metal on the vehicle frame as shown.
SECTION 5 − INSTALLATION
Y Always securely fasten welding generator
onto transport vehicle or trailer and comply
with all DOT and other applicable codes.
2
GND/PE
Airflow Clearance
(460 mm)
18 in
(460 mm)
18 in
(460 mm)
OR
3
1
18 in
18 in
(460 mm)
18 in
(460 mm)
Shown with
optional
running gear.
Ref 151 556 / Ref. 800 652 / 803 594-B / S-0854
Y Always ground generator
frame to vehicle frame to pre-
vent electric shock and static
electricity hazards.
1
Metal Vehicle Frame
2
Equipment Grounding
Terminal
3
Grounding Cable
Use #10 AWG or larger insulated
copper wire.
Y If unit does not have GFCI
receptacles,
use
protected extension cord.
install1 11/02* − Ref. 151 556 / S-0854
OM-4417 Page 13
GFCI-