INDOOR AIR QUALITY FUNCTIONS
HUMIDITY CONTROL
(CONTINUED)
Humidity Control Screen with only Dehumidification Installed
If dehumidification is done with the air conditioner, the Home Comfort Control will cool up to 3°F beyond the
cooling setpoint for dehumidification . Note overcooling may not be sufficient to meet the dehumidification setpoint .
20
INDOOR AIR QUALITY FUNCTIONS
FRESH AIR
Press [FRESH AIR] on the Home screen to enter the
Fresh Air screen .
DEHUMIDIFICATION SETPOINT
DEHUMIDIFIER ADJUSTMENT
DONE BUTTON
(EXIT HUMIDITY CONTROL)
If ventilation is installed, Fresh Air can operate in four
different modes .
Off: Ventilation will not run .
Automatic: Ventilation will cycle based on the
parameters set by the installer to meet your home's
ventilation requirements .
3 Hour Event: Ventilation will be constantly energized
for 3 hours and then the fresh air mode will return to Off
or Automatic (Hourly) depending on which mode was
most recently active . This option is used when fresh air
is needed . An example would be after cooking .
24 Hour Event: Ventilation will be constantly energized
for 24 hours and then the fresh air mode will return to
Off or Automatic (Hourly) depending on which mode was
most recently active . This option is used when a large
amount of fresh air is desired . An example would be a
day with desirable outdoor conditions .