ENGINE ADJUSTMENTS
NOTE:
WESTERBEKE recommends that the following engine
adjustments be performed by a competent engine mechanic.
The information below is provided to assist the mechanic.
VALVE CLEARANCE ADJUSTMENT
1. Remove the rocker cover and gasket.
2.
Rotate the crankshaft in the normal direction of rotation,
placing the No. 1 piston at the top of its compression
stroke with the exhaust and intake valves completely
closed. Adjust the intake and exhaust valves for No. 1
cylinder, the exhaust valve for No. 2 cylinder, and the
intake valve for No. 3 cylinder (see chart).
3. Rotate the crankshaft
1800
in its normal direction of
rotation. Locate the piston in No. 1 cylinder at the top of
its exhaust stroke. Adjust the intake valve for No. 2
cylinder and the exhaust valve for No. 3 cylinder (see
chart).
CYLINDER#
CRANK ANGLE
1
2
3
When No. 1 piston is set at top of IN
compression stroke
• •
EX
When No. 1 piston is positioned
IN
at top of exhaust stroke
EX
4 .. Replace the rocker cover along with a new rocker cover
gasket..
Rocker cover torque: 2.9-5.1 lb·lt (4- 7 Nm)
VALVE CLEARANCE
INTAKE VAlVES
0.20mm (.008in)
EXHAUST VALVES 0.30inm (.012in)'.
VALVE
CLEARANCE'
28
IGNITION TIMING
1. Attach a timing light to the #1 spark plug and mark the
front timing pointer to indicate 15°. Locate the timing
mark on the crankshaft pulley and mark it with white
chalk or a crayon.
2. Start the engine and warm it up to its normal operating
. temperature. Make sure the generator is operating without
a load on it.
3. Using the timing light, align the timing mark in the front
crankshaft pulley so it is just slightly before the first tim-
ing pointer. Do this by loosening and slowly rotating the
distributor body. Use the following timing specifications:
Timing Specifications: 15"
±
.5° BTDC at 1800 rpm
(no load on generator)
IGNITION TIMING
CHOKE SOLENOID
The choke solenoid is a 12 volt DC operated unit that func-
tions to close the choke plate
m
the carburetor when the ON
switch is depressed during engine start-up.
The choke solenoid de-energises once the engine starts and
the ON switch is released. Some unstable running may be
present when the engine starts cold, but should smooth out as
the engine reaches normal operating temperature.
Keep this solenoid
dry
and periodically lubricate the linkage,
plunger and choke shaft with graphite lube ..