Power Supply Case - Asus Xeon Tower/5U Rackmount Server AP1710-S5 User Manual

Intel xeon tower/5u rackmount server 533mhz front side bus support
Table of Contents

Advertisement

2.9.5 Power supply case

The redundant power modules are secured in a power supply case that
connects to various power supply connectors on the SCSI backplane and
the motherboard.
To remove the power supply case:
1. Remove the two (2) top
chassis cover screws to release
chassis top panel cover.
2. Remove all power cable
connections from SCSI
backplane and motherboard.
3. Remove the six (6) chassis bar
screws and release chassis bar.
4. Remove the two (2) right-side
chassis cover screws to release
right-side cover.
2-30
Chapter 2: Hardware setup

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ap1710-s5

Table of Contents