UC Living Arranmore SC Owner's Manual

Slide control

Advertisement

Quick Links

Arranmore Slide Control
OWNER MANUAL
INCLUDES
USER INSTRUCTION
&
INSTALLATION & MAINTENANCE
INSTRUCTIONS
Please read these instructions carefully before you start installing or using this
appliance
Keep this booklet handy for future reference
This appliance is
for use in Great Britain or
IRELAND only

Advertisement

Table of Contents
loading

Summary of Contents for UC Living Arranmore SC

  • Page 1 Arranmore Slide Control OWNER MANUAL INCLUDES USER INSTRUCTION & INSTALLATION & MAINTENANCE INSTRUCTIONS Please read these instructions carefully before you start installing or using this appliance Keep this booklet handy for future reference This appliance is for use in Great Britain or IRELAND only...
  • Page 2: Table Of Contents

    UC Living Arranmore Slide Control Instructions CONTENTS PAGE USERS INSTRUCTIONS SECTION ONE Introduction Consumer Protection Information Heath & Safety Notice Introduction Important Information SECTION TWO Operating Appliance Lighting the Appliance Lighting with match or taper SECTION THREE Cleaning Cleaning Trim and Fret or Fascia...
  • Page 3: Section One

    ‘hazardous waste and should be disposed of at a site licensed for the disposal of industrial waste. Introduction  The UC Living Arranmore SLIDE CONTROL as been designed and tested for use in GB (Great Britain) and IE (Ireland). ...
  • Page 4: Important Information

    UC Living Arranmore SC Users Instructions SECTION ONE Introduction Continued Important Information  The appliance is available in Natural Gas (G20 @ 20 mbar) or (G31 @ 37 mbar) The marking (G20 for natural gas)and (G31 for propane gas) on the packaging and the data badge specify the gas for which the appliance has been factory set.
  • Page 5: Section Two

    UC Living Arranmore SC Users Instructions SECTION TWO Operating the Appliance The full lighting procedure is as follows: - Push slide control lever down, as far as possible a clicking noise will be heard and the pilot will light, HOLD DOWN FIRMLY FOR ABOUT 20 SECONDS.
  • Page 6: Glass Cleaning

    UC Living Arranmore SC Users Instructions SECTION THREE Cleaning Continued Cleaning: Pilot Assembly (Before cleaning ensure that the appliance is turned off and cold) In some instances you may experience ignition problems even when the appliance is new. This may be due to the aeration hole in the pilot body (see photograph) being partial blocked with dust, pet hairs, or other foreign matter.
  • Page 7: Section Four

    UC Living Arranmore SC Users Instructions SECTION THREE Cleaning Continued REMOVING GLASS PANEL  Remove the trim, which is held in position with magnets.  Remove the fret and ash pan cover.  Lift of the canopy and remove. ...
  • Page 8 UC Living Arranmore SC Users Instructions SECTION THREE Cleaning Continued Coal Fuel Bed Layout Locate the Rear Matrix on the burner ensuring that the front edge is against the back of the burner slot and not on top of it.
  • Page 9 UC Living Arranmore Users Instructions SECTION FOUR Fuel Bed Cleaning and Layout Continued  Lay another row of loose coals as shown and refit glass panel, * Before fitting the pebble set loosen the burner securing screws and make sure that burner is pushed to the right side of the burner tray.
  • Page 10 UC Living Arranmore SC Users Instructions SECTION FOUR Fuel Bed Cleaning & Layout Continued  Lay one row of Pebbles as shown.  Lay one row of Pebbles as shown. LT---- (iss -- --/--)
  • Page 11 UC Living Arranmore SC Users Instructions SECTION FOUR Fuel Bed Cleaning & Layout Continued  Lay the two Oblong Pebble as shown.  Lay a further two large round pebble should bridge the gap between the front and rear row of pebble.
  • Page 12: Section Five

    UC Living Arranmore SC Users Instructions SECTION FIVE General Points Like all appliances incorporating an aerated burner a low frequency noise may be heard, particularly on the low setting, this is quite normal and does not affect the operation of the appliance.
  • Page 13: Installation Instructions

    UC Living Arranmore SC Installation Instructions SECTION SIX Appliance Data NATURAL GAS PROPANE GAS Gas Type: CATEGORY I 2 H CATEGORY I 3 P Gas Pressure: 20 mbar +/- 1.0mbar 37 mbar +/- 1.0mbar Pressure Test Point Location: Gas inlet elbow Gas Input: 5.5 kW Gross (Max.)
  • Page 14: Section Eight

    UC Living Arranmore SC Installation Instructions SECTION SEVEN Regulations and Warnings Continued The following are relevant codes of practice and British Standards: - B.S. 5871 B.S. 5440 PART 1 & PART 2 B.S. 6891 This appliance must be installed to current versions of the above standards and include any relevant amendments to:- The Building Regulations Issued By The Department Of The Environment.
  • Page 15 UC Living Arranmore SC Installation Instructions SECTION EIGHT Siting the Appliance Continued  CLASS TWO FABRICATED METAL A double-walled or insulated metal flue box built to the requirements of BS 715 with an insulated flue having a minimum diameter of 125 mm (5 ins) and a minimum effective overall height of 3 metres (10 ft).
  • Page 16 UC Living Arranmore SC Installation Instructions SECTION EIGHT Siting the Appliance Continued Heath or Plinth Mounted Hole In Wall When fire fitted with (No Plinth) STANDARD THREE SIDED When fire fitted with TRIM STANDARD FOUR SIDED TRIM Heath / Plinth Size...
  • Page 17: Section Nine

    UC Living Arranmore SC Installation Instructions SECTION NINE To Install the Appliance CHECKING THE FLUE AND FIRE OPENING  Check that the chimney conforms to the required specifications as previously stated. Examine the condition and carry out any remedial work including removing any debris from the base.
  • Page 18: Glass Panel Removal

    UC Living Arranmore SC Installation Instructions SECTION NINE To Install the Appliance continued GLASS PANEL REMOVAL  The trim, which is held in position with magnets.  Remove the fret and ash pan cover.  Lift of the canopy and remove.
  • Page 19 UC Living Arranmore SC Installation Instructions SECTION NINE To Install the Appliance continued FIXING FIRE INTO OPENING Method 1 (Screw Fix)  Mark the position of flange holes required in the fireplace front, drill and insert wall plugs (not supplied).
  • Page 20: Section Ten

    UC Living Arranmore SC Installation Instructions SECTION TEN Checking Operation of Fire CHECKING GAS SOUNDNESS  Turn on the gas supply to the appliance and check for soundness in accordance with current codes of practice.  Turn off the gas supply at the external Isolation valve.
  • Page 21 UC Living Arranmore SC Installation Instructions SECTION TEN Checking Operation of Fire CHECKING GAS SOUNDNESS  Turn on the gas supply to the appliance and check for soundness in accordance with current codes of practice.  Turn off the gas supply at the external Isolation valve.
  • Page 22: Maintenance Instructions

    UC Living Arranmore SC Installation Instructions SECTION TEN Checking Operation of Fire  If spillage is detected the cause must be discovered and the fault corrected, if the fault cannot be corrected, disconnect the fire from the gas supply and seek expert advice. Spillage can be caused by a restriction in the flue system, down draught or insufficient ventilation into the room where the fire is installed.
  • Page 23: Replacement Of Gas Control

    UC Living Arranmore SC Maintenance Instructions SECTION ELEVEN Maintenance Continued REPLACEMENT OF GAS CONTROL AND OR THE SPARK GENERATOR Turn off the gas supply by isolating cock. Lift away carefully fire fret trim and fascia. Remove glass assembly. Lift away carefully all loose fuel bed components.
  • Page 24 UC Living Fires UC Living Arranmore SC THIS IS YOUR EXTENDED FIVE YEAR PARTS WARRANTY PLEASE READ IT CAREFULLY AND ENSURE YOUR INSTALLER HAS FILLED IN THE FIRST PORTION, KEEP IT IN A SAFE PLACE SO THAT IT IS AVAILABLE...
  • Page 25 For future reference we suggest you record the following details here, and keep the receipt as proof of purchase. This information may be asked for when you contact the helpdesk. Model: UC Living Arranmore SC Serial No. This information can be found on the label attached to the packaging and on the data badge, which is located on the appliance behind the trim or fascia.
  • Page 26: Service Log

    Gas Safe Registration No. Date of Third annual service: Engineer Name Gas Safe Registration No. Date of Fourth annual service: Engineer Name Gas Safe Registration No. UC Living 27 Fernbank Road Bangor BT19 6GA Telephone 353 4854325 E-mail : info@ucliving.co.uk www.ukliving.co.uk...
  • Page 27 Post Code TELEPHONE No. PRODUCT DETAILS Model: : UC Living Arranmore SC Serial No. Date of Purchase This information can be found on the label attached to the packaging and on the data badge, which is located on the appliance behind trim.
  • Page 28 UC Living Arranmore S/C NG– Coal UC Living Arranmore S/C NG– Pebble Product Product Serial No Serial No ID Label ID Label Prefix Prefix (NG) (NG) Burner Tray / Box Assembly Burner Tray / Box Assembly Restrictor Elbow (2194) Restrictor Elbow (2194)

Table of Contents