All electrical work should be
undertaken by a suitably qualified
and competent person in strict
accordance with current national
and local safety regulations
(BS 7671 in the UK).
Installation, repairs and other work
by unqualified persons could be
dangerous. The manufacturer
cannot be held liable for
unauthorised work.
Ensure power is not supplied to the
appliance until after installation or
repair work has been carried out.
The voltage and connected load are
given on the data plate, visible below
the oven interior, with the oven door
open. Ensure that these match the
household mains supply. Please quote
these data, and the model and serial
number when contacting the Miele
Service dept.
Connection of this appliance should be
made via a suitable isolator, which
complies with national and local safety
regulations, and the on/off switch
should be easily accessible after the
appliance has been built in.
If the switch is not accessible after
installation (depending on country) an
additional means of disconnection must
be provided for all poles.
For extra safety it is advisable to install
a residual current device with a trip
current of 30 mA (in accordance with
DIN VDE 0664, VDE 0100 Section 739).
When switched off there must be an
all-pole contact gap of 3 mm in the

Electrical connection UK, IRL, ZA

isolator switch (including switch, fuses
and relays acc. to EN 60 335).
Important U.K.
This appliance is supplied with a 3-core
cable for connection to a single phase
230-240 V 50 Hz supply.
The wires are coloured in accordance
with the following code:
Green/yellow = earth
Blue
Brown
In other countries check these details
with your supplier.
WARNING
THIS APPLIANCE MUST BE
EARTHED.
= neutral
= live