Hide thumbs Also See for QML Series:

Advertisement

Available languages

Available languages

QML Series
Range Hoods
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufac-
turer. If you have questions, contact the manufacturer at the
address or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the ser-
vice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable codes
and standards, including fire-rated construction.
4. Sufficient air is needed for proper combustion and exhaust-
ing of gases through the flue (chimney) of fuel burning equip-
ment to prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society of Heating, Refrigeration and Air
Conditioning Engineers (ASHRAE), and the local code au-
thorities.
5. This product may have sharp edges. Be careful to avoid cuts
and abrasions during installation and cleaning.
6. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
7. Ducted fans must always be vented to the outdoors.
8. Use only metal ductwork.
9. Do not use this fan with any solid-state speed control device.
10. As an alternative, this product may be installed with the UL-
approved cord kit designated for the product, following in-
structions packed with the cord kit.
11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings.
Boilovers cause smoking and greasy spillovers that may ig-
nite. Heat oils slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when
flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Pep-
percorn Beef Flambé).
3. Clean ventilating fans frequently. Grease should not be al-
lowed to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for
the size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE
FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet,
or metal tray, then turn off the burner. BE CAREFUL TO
PREVENT BURNS. If the flames do not go out immediately,
EVACUATE AND CALL THE FIRE DEPARTMENT.
Register your product online
at: www.broan.com
FOR DOMESTIC COOKING ONLY
WARNING
2. NEVER PICK UP A FLAMING PAN — You may be burned or
spread the fire.
3. DO NOT USE WATER, including wet dishcloths or towels - a
violent steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher, and you
already know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Firesafety Tips" published by NFPA.
CAUTION
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust haz-
ardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbal-
anced impeller, keep drywall spray, construction dust, etc.,
off power unit.
4. Do not use over cooking equipment greater than 60,000
BTU/hr.
5. Your hood motor has a thermal overload which will automati-
cally shut off the motor if it becomes overheated.
6. The bottom of the hood MUST NOT BE LESS than 18" and at
a maximum of 24" above cooktop for best capture of cooking
impurities.
7. Please read specification label on product for further infor-
mation and requirements.
NOTE If hood is to be installed non-ducted:
Purchase non-ducted filter (Model BPQTF) from your
local distributor or retailer.
Installer: Leave this manual
with the homeowner.
Homeowner: Cleaning, Maintenance and
Operating instructions on page 2.
QML SERIES
Page 1

Advertisement

Table of Contents
loading

Summary of Contents for Broan QML Series

  • Page 1 QML SERIES Page 1 QML Series Register your product online at: www.broan.com Range Hoods READ AND SAVE THESE INSTRUCTIONS FOR DOMESTIC COOKING ONLY WARNING WARNING TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN- 2. NEVER PICK UP A FLAMING PAN — You may be burned or JURY TO PERSONS, OBSERVE THE FOLLOWING: spread the fire.
  • Page 2: Light Bulb Replacement

    QML SERIES Page 2 OPERATION Stainless Steel Cleaning Always turn the hood ON before cooking in order to establish an • Regularly wash with clean cloth or rag soaked with warm water air flow in the kitchen. After turning off the range, let the hood run and mild soap or liquid dish detergent. for a few minutes to clear the air. • Always clean in the direction of original polish lines. Operate the hood as follows: • Always rinse well with clear water (2 or 3 times) after cleaning. Wipe dry completely. • You may also use a specialized household stainless steel cleaner. DON’T: • Use any steel or stainless steel wool or any other scrapers to remove stubborn dirt. • Use any harsh or abrasive cleansers. • Allow dirt to accumulate.
  • Page 3: Install Ductwork

    QML SERIES Page 3 INSTALL DUCTWORK PREPARE HOOD LOCATION (Ducted Hoods Only) Use the proper diagram below for placement of ductwork and electrical cutout in cabinet or wall. For a non-ducted installation, DO NOT cut a duct access hole. ROOF CAP 3¼" X 10" or 3¼” X 10” 7" ROUND DUCT VERTICAL DUCTING (For vertical HOOD MOUNTING SCREWS (5) discharge) 15 / 15 / "(30"...
  • Page 4: Prepare The Hood

    QML SERIES Page 4 CONTENTS 7” ROUND DUCT PLATE (1) 3¼” X 10” (1) 7” ROUND (1) GREASE DAMPER / DUCT DUCT FILTER CONNECTOR CONNECTOR (1) PARTS BAG CONTAINING: BULB #10 X 5/8” SUCTION 12 Remove 7” Round Duct Plate from top/back of hood. RD. HD.
  • Page 5: Install The Hood

    QML SERIES Page 5 INSTALL THE HOOD 7” ROUND KNOCKOUT PLATE (also WARNING remove 3¼” x 10” To reduce the risk of electrical shock, switch power off vertical plate) at service panel. Lock or tag service panel to prevent power from being switched on accidentally. 3¼” X 10” VERTICAL KNOCKOUT 3¼” X 10” PLATE HORIZONTAL ELECTRICAL KNOCKOUT POWER PLATE CABLE KNOCKOUT 16 DUCTED INSTALLATION ONLY: Remove 3¼” x 10 vertical, 3¼” x 10” horizontal, or 7-inch round knockout plate(s) as appropriate for your ducting Remove Electrical Wiring Box Cover from inside method.
  • Page 6: Connect The Wiring

    QML SERIES Page 6 CONNECT THE WIRING LAMP SOCKET BRACKET GROUND SCREW SCREWS HOUSE To change the depth of bulb sockets: POWER CABLE - Remove bottom panel (See Step 10). - Disconnect light harness. - Loosen 2 Screws holding Lamp Socket Bracket to Connect House Power Cable to range hood wiring - Light Panel. BLACK to BLACK, WHITE to WHITE, and GREEN or - Adjust socket/bracket to desired depth. BARE WIRE to Ground Screw. Replace electrical wiring - Re-tighten screws securely. box cover. - Re-attach light harness and replace bottom panel. Re-connect lamp wire harness and re-attach bottom panel with (8) screws as shown in Step 10. DUCTED INSTALLATION ONLY: INSTALL LIGHT BULBS Re-install aluminum filters removed in Step 9.
  • Page 7: Service Parts

    QML SERIES Page 7 SERVICE PARTS NO. DESCRIPTION PART NO. BOTTOM PANEL ASSEMBLY, WHITE 97018651 BOTTOM PANEL ASSEMBLY, BLACK 97018652 BOTTOM PANEL ASSEMBLY, STAINLESS STEEL 97018653 SCREW PACKAGE #8-18 X 3/8 (2 SCREWS) R602534 LAMP WIRE HARNESS 97018656 MOTOR WIRE HARNESS 97018659 AIR CHUTE 97018660 SWITCH, WHITE (2 REQUIRED) 97017300 SWITCH, BLACK (2 REQUIRED) 97018658 FAN BLADE (INCLUDES HAIRPIN CLIP) R531076 HAIRPIN CLIP R99420635 PARTS BAG ASSEMBLY 97018623 FILTER, ALUMINUM R610092 7” ROUND DUCT PLATE (INCLUDES MOUNTING HARDWARE) R680508 3-1/4” X 10” DAMPER ASSEMBLY(INCLUDES MOUNTING HARDWARE) R740014 MOTOR...
  • Page 8 To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At the time of requesting warranty service, you must present evidence of the original purchase date.
  • Page 9 SERIE QML Página 9 Campanas Registre su producto en el Serie QML sitio web www.broan.com LEA Y CONSERVE ESTAS INSTRUCCIONES SOLAMENTE PARA COCINAR EN CASA ADVERTENCIA ADVERTENCIA PARA REDUCIR EL RIESGO DE LESIONES A LAS PERSONAS EN CASO DE PARA REDUCIR EL RIESGO DE INCENDIO, DESCARGA ELÉCTRICA...
  • Page 10 SERIE QML Página 10 FUNCIONAMIENTO Limpieza del acero inoxidable COSAS QUE PUEDE HACER: ENCIENDA siempre la campana antes de comenzar a cocinar, • Regularmente, lave con una tela o trapo limpio remojado con agua con el fin de establecer un flujo de aire en la cocina. Después de tibia y jabón o detergente líquido para platos. apagar la estufa, deje que la campana funcione durante unos • Siempre limpie en la dirección de las líneas originales de pulido. cuantos minutos para despejar el aire. • Siempre enjuague bien con agua limpia (2 o 3 veces) después de la Para hacer funcionar la campana, haga lo siguiente: limpieza. Deje totalmente seco. • También puede usar un limpiador casero especializado para acero inoxidable. COSAS QUE NO DEBE HACER: • Usar lana de acero o acero inoxidable ni algún otro tipo de raspador para quitar mugre difícil de sacar.
  • Page 11 SERIE QML Página 11 INSTALE EL SISTEMA CONDUCTO VERTICAL DE TORNILLOS DE MONTAJE 3¼ X 10 PULG. (8.3 X 25.4 CM) DE CONDUCTOS DE LA CAMPANA (5) 13-15/16 pulg. (35.4 cm) 13-15/16 pulg. (35.4 cm) (Sólo campanas para (campana de 30 pulg./76.2 cm) (campana de 30 pulg./76.2 cm) FRENTE DEL GABINETE sistemas con conductos)
  • Page 12 SERIE QML Página 12 CONTENIDO PLACA DEL CONDUCTO REDONDO DE 7 PULG. (17.8 CM) (1) CONECTOR PARA (1) CONECTOR (1) FILTRO REGULADOR/CONDUCTO PARA CONDUCTO DE GRASA DE 3¼ X 10 PULG. REDONDO (8.3 X 25.4 CM) DE 7 PULG. (17.8 CM) (1) BOLSA DE PIEZAS QUE CONTIENE: (5) TORNILLOS DE (1) HERRAMIENTA Retire la placa del conducto redondo de 7 pulg.
  • Page 13: Instale La Campana

    SERIE QML Página 13 INSTALE LA CAMPANA PLACA REDONDA DE ORIFICIO CIEGO DE 7 PULG. (17.8 CM) (TAMBIÉN DESMONTE LA PLACA ADVERTENCIA VERTICAL DE 3¼ X 10 PULG. P ara reducir el riesgo de una descarga eléctrica, [8.3 X 25.4 CM]) desconecte el suministro eléctrico en el panel de servicio. Bloquee el panel de servicio o póngale una etiqueta de seguridad para evitar que alguien conecte accidentalmente la energía eléctrica. PLACA HORIZONTAL DE ORIFICIO CIEGO DE 3¼ X 10 PULG. (8.3 X 25.4 CM) PLACA VERTICAL DE ORIFICIO CIEGO DE 3¼ X 10 PULG. ORIFICIO (8.3 X 25.4 CM) CIEGO DEL CABLE ÚNICAMENTE EN INSTALACIONES CON CONDUCTOS: 16 ELÉCTRICO Retire las placas de orificio ciego vertical de 3¼ x 10 pulg. (8.3 x 25.4 cm), horizontal de 3¼ x 10 pulg. (8.3 x 25.4 cm), o redonda de 7 pulg. (17.8 cm), según corresponda a su método de conductos.
  • Page 14 SERIE QML Página 14 CONECTE EL CABLEADO SOPORTE DEL RECEPTÁCULO DE LA LÁMPARA TORNILLO DE TIERRA TORNILLOS CABLE ELÉCTRICO Para cambiar la profundidad de los receptáculos de las bombillas: DE LA CASA - Quite el panel inferior (vea el paso 10). - Desconecte el arnés de las luces. Conecte el cable eléctrico de la casa al cableado de - A floje los 2 tornillos que sostienen el soporte del la campana: cable NEGRO con NEGRO, BLANCO con receptáculo de la lámpara al panel de iluminación. BLANCO y VERDE o SIN FORRO al tornillo de tierra. - Ajuste el receptáculo/soporte a la profundidad deseada. Vuelva a colocar la cubierta de la caja de cableado eléctrico.
  • Page 15 SERIE QML Página 15 PIEZAS DE SERVICIO CLAVE DESCRIPCIÓN PIEZA N. CONJUNTO DE PANEL INFERIOR, BLANCO 97018651 CONJUNTO DE PANEL INFERIOR, NEGRO 97018652 CONJUNTO DE PANEL INFERIOR, ACERO INOXIDABLE 97018653 PAQUETE DE TORNILLOS #8-18 x 3/8 (2 TORNILLOS) R602534 ARNÉS DE CABLES DE LA LÁMPARA 97018656 ARNÉS DE CABLES DEL MOTOR 97018659 CONDUCTO PARA AIRE 97018660 INTERRUPTOR, BLANCO (SE REQUIEREN 2) 97017300 INTERRUPTOR, NEGRO (SE REQUIEREN 2) 97018658 ASPA DEL VENTILADOR (INCLUYE PASADOR DE HORQUILLA) R531076 PASADOR DE HORQUILLA R99420635 CONJUNTO DE LA BOLSA DE PIEZAS 97018623 10 FILTRO DE ALUMINIO R610092 11 PLACA REDONDA DE 7 PULG. (17.8 CM) (INCLUYE PIEZAS DE MONTAJE) R680508 12 C ONJUNTO DEL REGULADOR DE TIRO DE TIRO DE 3¼ X 10 PULG.
  • Page 16 DE TECHO O DE PARED Y DEMÁS ACCESORIOS DE CANALIZACIÓN. Esta garantía no cubre (a) mantenimiento y servicio normales, ni (b) ningún producto o piezas que se hayan sometido a uso inadecuado, negligencia, accidente, mantenimiento o reparación inadecuada (no hecha por Broan-NuTone), instalación incorrecta o instalación en contra de las instrucciones de instalación recomendadas. La duración de cualquier garantía implícita se limita al período de un año, como se especifica para la garantía expresa. Algunos estados no permiten limitaciones en cuanto al tiempo de vencimiento de una garantía implícita, por lo que la limitación antes mencionada podría no aplicarse a usted. LA OBLIGACIÓN DE BROAN-NUTONE DE REPARAR O REEMPLAZAR, A CRITERIO DE BROAN-NUTONE, SERÁ EL ÚNICO Y EXCLUSIVO RECURSO DEL COMPRADOR BAJO ESTA GARANTÍA. BROAN-NUTONE NO SERÁ RESPONSABLE POR DAÑOS INCIDENTALES, RESULTANTES O ESPECIALES QUE SURJAN DEL USO O DESEMPEÑO DEL PRODUCTO O EN RELACIÓN CON EL MISMO. Algunos estados no permiten la exclusión o limitación de daños incidentales o resultantes, por lo que la limitación antes mencionada podría no aplicarse a usted. Esta garantía le otorga derechos legales específicos, y usted podría tener otros derechos que varían de un estado a otro. Esta garantía sustituye todas las garantías anteriores. Para tener derecho al servicio de la garantía, usted debe (a) notificar a Broan NuTone a la dirección y número de teléfono que aparecen abajo, (b) proporcionar el número de modelo y la identificación de la pieza y (c) describir la naturaleza de cualquier defecto en el producto...

Table of Contents