Colormetrics P2000 User Manual

Hide thumbs Also See for P2000:

Advertisement

Quick Links

P2000

User Manual

Version 1.2
Errors excepted; subject to change
www.colormetrics.com.tw

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Colormetrics P2000

  • Page 1: User Manual

    P2000 User Manual Version 1.2 Errors excepted; subject to change www.colormetrics.com.tw...
  • Page 2 Colormetrics P2000 www.colormetrics.com.tw...
  • Page 3: Table Of Contents

    4-2. MagStripe Card Reader Configuration Utility 4-3. Fingerprint Reader 4-4. RFID inTernal VfD (opTional) 5-1. VFD Specification seTup sofTware guiDe bios/uTiliTy seTup Advanced BIOS Features Advanced Chipset Features Integrated Peripherals SuperIO Device (Press Enter) Power Management Setup LCD Surface Cleaning www.colormetrics.com.tw Colormetrics P2000...
  • Page 4: Copyright

    We reserve the right to revise this document or make changes in the specifications of the product described therein at any time without notice and without obligation to notify any person of such revision or change. Colormetrics P2000 www.colormetrics.com.tw...
  • Page 5: Safety Instructions

    Dispose used batteries according to the manufacture’s instructions. Do not remove the cover, and ensure no user serviceable components are inside. Take the unit to the service center for service and repair. www.colormetrics.com.tw Colormetrics P2000...
  • Page 6: Packing List

    1-1. standard accessories a. System (with stand) b. Power Adapter c. Power Cord d. Driver Bank e. Screw f. Cable Cover Colormetrics P2000 www.colormetrics.com.tw...
  • Page 7: System View

    5. COM2 13. COM1 6. COM3 14. Parallel port(Option) 7. VGA 15. Power Button el port(Option) *Please make sure 19V DC plug in the right r Button direction before plugging in DC jack. CF CARD www.colormetrics.com.tw Colormetrics P2000 smart card/IBUTTON/Fingerprint/RFID(Option) Option)
  • Page 8: Specification

    Storage Temperature -20°C ~ 60°C Storage Humidity 20% ~ 80%, non-condensing Display LCD Panel Size 15-inch TFT Active Matrix Display Resolution 1024*768 Pixels Brightness 250 cd/m2 Touch Panel 5-wire Resistive Type / Projected Capacitive Type Tilt Angle 30°~90° Colormetrics P2000 www.colormetrics.com.tw...
  • Page 9: Internal Layout

    2-3. internal layout www.colormetrics.com.tw Colormetrics P2000...
  • Page 10: Pin Definition

    NRTS ERR# Printer Error NRTS INIT# Printer Initialize NCTS SLIN# Printer Select Input NTXD Ground NRXD Ground Ground Ground +12V 2. Jumper for Cf CarD selection Pin NO. Pin Name Description CF POWER CF POWER 3.3V +3.3V Colormetrics P2000 www.colormetrics.com.tw...
  • Page 11 LVDS Output DATA0- DATA 0+ LVDS Output DATA0+ Ground DATA 1- LVDS Output DATA1- DATA 1+ LVDS Output DATA1+ Ground DATA 2- LVDS Output DATA2- DATA 2+ LVDS Output DATA2+ Ground CLK- LVDS CLK- CLK+ LVDS CLK+ Ground Ground www.colormetrics.com.tw Colormetrics P2000...
  • Page 12: Rear I/O Interface

    3. USB port Red Analogue Ground +5V DC Green Analogue Ground Clock Blue Analogue Ground Not Connected Key (Plugged Hole) Sync Ground Monitor ID 0 Monitor ID 1 4. PS/2 K/B port Horizonal Sync Vertical Sync Monitor ID 3 Colormetrics P2000 www.colormetrics.com.tw...
  • Page 13 Drawer Kick-out Output drive signal 1 +12V Signal GND Example DOS COMMAND for Cash Drawer: 1. Create the file: TEST.TXT 2. Input below contents in TEST.TXT ConTeXT-"000.0” moDe Com6:300 3. Run COMMAND under DOS mode Copy TesT.TXT Com6 www.colormetrics.com.tw Colormetrics P2000...
  • Page 14: System Assembly & Disassembly

    4. Place the HDD bracket back to the module 5-2. MSR 3-2. Cf-Card 1. Please notice the notched CF Card. This side up. 1. Open the MSR cover 2. Single MSR or 4in1MSR 3. Screw*2 M3x10L 4. Fasten the screw Colormetrics P2000 www.colormetrics.com.tw 5-3. UPS Battery...
  • Page 15 2. Before Installing CF Card. 3. After Installing CF Card. www.colormetrics.com.tw Colormetrics P2000...
  • Page 16: Msr

    Place the battery pack in position of the Stand Bracket. and bind the cable ties tightly. Then cut the ning hole extra tail from cable ties. Colormetrics P2000 www.colormetrics.com.tw e the cable from the battery pack through the stand bracket and click the...
  • Page 17: Cable Cover

    Then fasten 2 screws (M3*5L). Assemble the cable cover from bottom and make sure the two latches are on the right position. Then fasten 2 screws (M3*5L). ” 2 Display www.colormetrics.com.tw Colormetrics P2000 15” 2 Display...
  • Page 18: 8"/15" 2Nd Display

    5) Connect the VGA cable as shown in figure . onnect the COM port, DC cable as shown in figure (Please refer to page 0 to set the COM port pin9 with 12V DC output.)  onnect the VGA cable as shown in figure Colormetrics P2000 www.colormetrics.com.tw...
  • Page 19 Audio cable as shown in figure . (11) Connect the DC power cable as shown in figure . (12) Connect the VGA cable as shown in figure www.colormetrics.com.tw Colormetrics P2000 . (13) Connect the Audio cable as shown in figure...
  • Page 20 (11) Connect the DC power cable as shown in figure (1). (12) Connect the VGA cable as shown in figure (2). (13) Connect the Audio cable as shown in figure (3). (14) Put the cable cover on the hinge of VESA bracket. Colormetrics P2000 www.colormetrics.com.tw...
  • Page 21: Wi-Fi

    2. After fastening the Wi-Fi Module to the Rubber (Part No.: 78D200655-000T), fix this on the VFD cover. The left side of Wi-Fi module should align the interior cover as the position of the red line. The right side of Wi-Fi module should align another side as the red circle. www.colormetrics.com.tw Colormetrics P2000...
  • Page 22 5. Fasten the VFD cover to the rear lid. Push the snap of the top VFD cover into the slot of rear lid and fasten the bottom cover with 2 screws (Part No.: 64D430088-000T). Then connect Wi-Fi /MSR cable (Part No.:35D510522-000B) to Wi-Fi module Colormetrics P2000 www.colormetrics.com.tw...
  • Page 23: 2D / Ibutton With Rfid Module

    Connect the cable as shown. * Before COM port cable connection, please setup COM port PIN9 with 5V DC output from BIOS setup. Please refer to page 61, advanced Chipset features / COM port PIN9 setting. www.colormetrics.com.tw Colormetrics P2000...
  • Page 24: Device Driver Installation

    DeViCe DriVer insTallaTion 4-1. resistive Type Touch panel 1. Click “Next” 2. Click “Next” Colormetrics P2000 www.colormetrics.com.tw...
  • Page 25 3. Click “Next” 4. Select “None”, Click “Next”. www.colormetrics.com.tw Colormetrics P2000...
  • Page 26 5. Click “OK” 6. Select “Support Multi-Monitor System”, Click “Next”. 1.6 Click Finish to reboot your system to complete the installation of POS touch driver. Colormetrics P2000 www.colormetrics.com.tw...
  • Page 27 7. Click “Next”. 8. Click “Next”. 2.4 Follow the instruction to touch four cross points. www.colormetrics.com.tw Colormetrics P2000...
  • Page 28 9 Click “Next” 10. Select “Create a eGalaxTouch Utility shortcut on desktop”, Click “Next”. Colormetrics P2000 www.colormetrics.com.tw...
  • Page 29 11. Would you do 4 point calibration now? Click “Yes”. www.colormetrics.com.tw Colormetrics P2000...
  • Page 30 12. Do 4 points aligrment to match display 13. Calibration utility Colormetrics P2000 www.colormetrics.com.tw...
  • Page 31: Magstripe Card Reader Configuration Utility

    3 Follow the wizard to complete the installation. launching program Below steps guide you how to load the Utility program. 1 From Start/Programs, click HID_MSR2 folder 2 Click MagStripe Card Reader Configuration Utility to launch the program. www.colormetrics.com.tw Colormetrics P2000...
  • Page 32 6 Decode Mode: Determines the way of outputting the three tracks data. Shown below is the data structure of the output string for MSR. PP PR1 SS1 TK1 ES1 SU1 PR2 SS2 TK2 ES2 SU2 PR3 SS3 TK3 ES3 SU3 SU DM Colormetrics P2000 www.colormetrics.com.tw...
  • Page 33 For this group, it contains two kinds of settings, which are: 1 Track Data Filtering: Determine which track to be, not to be output or needed to be output. 2 Switch Output Order: Change the output order of track 1 ~ 3. www.colormetrics.com.tw Colormetrics P2000...
  • Page 34 Open Settings To load pre-saved settings, click Open, specify the settings file, and then click OK to load into program. Restore MSR Reader Settings To load restore settings of connected MSR reader, click Restore ES2: End sentinel for trac Colormetrics P2000 www.colormetrics.com.tw...
  • Page 35: Fingerprint Reader

    4-3. fingerprint reader Step 1 Check Fingerprint reader be detected by “Device manager” Step 2 Unzip and run setup.exe from the following folder. www.colormetrics.com.tw Colormetrics P2000...
  • Page 36 Colormetrics P2000 www.colormetrics.com.tw...
  • Page 37 Colormetrics P2000...
  • Page 38 Colormetrics P2000 www.colormetrics.com.tw...
  • Page 39 Colormetrics P2000...
  • Page 40 Step 3 Restart system Step 4 Check Fingerprint reader in device without any extraordinary. Colormetrics P2000 www.colormetrics.com.tw...
  • Page 41 Step 5 Launch Fingerprint reader from start menu www.colormetrics.com.tw Colormetrics P2000...
  • Page 42 Colormetrics P2000 www.colormetrics.com.tw...
  • Page 43 Step 6 Enroll the fingerprint by the “enrollment” www.colormetrics.com.tw Colormetrics P2000...
  • Page 44 Step 7 Select “Fingerprint Enrollment” Colormetrics P2000 www.colormetrics.com.tw...
  • Page 45 Step 8 Put your finger on fingerprint reader and follow the direction to enroller your fingerprint, it need scan your fingerprint 4 times Step 9 after enroller finish it will popup a dialog box www.colormetrics.com.tw Colormetrics P2000...
  • Page 46: Rfid

    1.2.2 1.1 Check the Device Manager to verify the status of RFID reader. Computer Management -> Device Manager -> Other devices (The device will show a question mark if the installation is not done properly.) 1.2 Install RFID driver file name: XP2KxVista.exe 2-1 Path:\USB Driver\ XP2KxVista.exe Colormetrics P2000 www.colormetrics.com.tw...
  • Page 47 1.2.1 After clicking Next, A pop up console window appears as below. 1.2.2 Check the Device Manager to verify the status of RFID reader. Computer Management -> Device Manager -> Ports (COM & LPT) www.colormetrics.com.tw Colormetrics P2000...
  • Page 48 1.3 install RFID utility MifareDemoSetup_PSW00020.exe 3-1 Path:\MF320\MifareDemoSetup_PSW00020.exe Colormetrics P2000 www.colormetrics.com.tw...
  • Page 49 1.3.1 InstallaShield Wizard will be activated. 1.3.2 Click “Next” www.colormetrics.com.tw Colormetrics P2000...
  • Page 50 1.3.3 Click “Next” 1.3.4 Click “Giga-TMS” & “Next” Colormetrics P2000 www.colormetrics.com.tw...
  • Page 51 1.3.5 Click “Next” 1.3.6 Click “Next” www.colormetrics.com.tw Colormetrics P2000...
  • Page 52 2 Run RFID demo program. Start -> All Programs -> GIGA-TMS -> Mifare Demo 2-1 Run “Auto Scan” Demo AP will detect the RFID reader automatically. Or select the RFID COM port Colormetrics P2000 www.colormetrics.com.tw...
  • Page 53 2-2 After finishing the AutoScan, Request box will be ready for the click and Reader Version will show on the position as marked. (Reader Version: PGM-T1235 V1.0R3 (101230) Place Mifare Card to the RFID reader area. Event Dialog window gets the data from the Mifare Card Close the RFID card to RFID reader www.colormetrics.com.tw Colormetrics P2000...
  • Page 54 2-3 Card type will be recognized when you click “Request”. (Your Mifare card should be placed on the RFID reader area.) 2-4 Card ID will be recognized when you click “Card ID”. Colormetrics P2000 www.colormetrics.com.tw...
  • Page 55 2-5 SAK will be read when you click “Select”. 2-6 The result will show when you click “Authenticate” www.colormetrics.com.tw Colormetrics P2000...
  • Page 56: Internal Vfd (Optional)

    Norwegian, Polish, Portuguese, Romanian, Russian, Slo- vene, Slovak, Spanish, Swedish interface RS-232 (serial) / USB reliability baud rate Direct connection 9600 or 19,200 bps Connection mTbf 30,000 hours power Consumption 5~12 VDC emC standards safety FCC, CE safety standards Colormetrics P2000 www.colormetrics.com.tw...
  • Page 57: Setup Software Guide

    3. “Get Setting From VFD” button To get all setting from the display and It´ll refresh the “VFD_Setup.exe” utility 4. “Character Type” / “Comand Mode” / “BaudRate Selcet” / “Passthru Mode” Please refer to Chapter 4-5 user manual www.colormetrics.com.tw Colormetrics P2000...
  • Page 58 You can type the character by keyboard (0x20h˜0x7Fh), if you press clear icon, it will clear the all Msg charaters on AP. b. Hex mode Hex mode can define the character from 0x20h to 0xFFh, the range 0x80˜0xFF Colormetrics P2000 www.colormetrics.com.tw...
  • Page 59: Bios/Utility Setup

    Press <DEL> key to enter BIOS SETUP UTILITY when system boot up. www.colormetrics.com.tw Colormetrics P2000...
  • Page 60 HDD´s size, Precom head... on this channel Landing Zone Sector iDe hDD auto-Detection Press <Enter> while this item is highlighted to prompt the Setup Utility to automatically detect and configure an IDE device on the IDE channel. Colormetrics P2000 www.colormetrics.com.tw...
  • Page 61: Advanced Bios Features

    ^ v: Move PU/PD/+/-/: Change Priority F10: Save ESC:Exit first/second boot Device (floppy/hard Disk/CDrom) Use these three items to select the priority and order of the devices that your system searches for an operating system at start-up time. www.colormetrics.com.tw Colormetrics P2000...
  • Page 62: Advanced Chipset Features

    Select “COM1/2/3 PIN9 Function” and press <Enter> to setup COM 1/2/3 PIN9 function. ITEM Option Descriptions COM1 PIN9 Function RING (Default) COM1/2/3 Pin9 select RING function COM2 PIN9 Function COM1/2/3 Pin9 select 5V function COM3 PIN9 Function COM1/2/3 Pin9 select 12V function Colormetrics P2000 www.colormetrics.com.tw...
  • Page 63: Integrated Peripherals

    These options display items that define the operation of peripheral components on the system’s input/ output ports. superio Device (press enter) Scroll to this item and press <Enter> to view the following screen: www.colormetrics.com.tw Colormetrics P2000...
  • Page 64: Power Management Setup

    When set to Enabled, additional fields become available and you can set the date (day of the month), hour, minute and second to turn on your system. When set to 0 (zero) for the day of the month, the alarm will power on your system every day at the specified time. Colormetrics P2000 www.colormetrics.com.tw...
  • Page 65: Enter Password

    Highlight this item and press <Enter> to discard any changes that you have made in the Setup Utility and exit the Setup Utility. When the Exit Without Saving dialog box appears, press <Y> to discard changes and exit, or press <N> to return to the main menu. www.colormetrics.com.tw Colormetrics P2000...
  • Page 66: Lcd Surface Cleaning

    3. what types of cleaners are acceptable? • Water • Vinegar (mixed with water) • Isopropyl Alcohol noTiCe: The following cleaners are unacceptable: • Acetone • Ethyl alcohol • Ethyl acid • Ammonia • Methyl chloride Colormetrics P2000 www.colormetrics.com.tw...
  • Page 67 (WEEE). The Directive determines the framework for the return and recycling of used appliances as applicable throughout the European Union. This label is applied to various products to indicate that the product is not to be thrown away, but rather reclaimed upon end of life per this Directive. www.colormetrics.com.tw Colormetrics P2000...
  • Page 68 Colormetrics P2000 www.colormetrics.com.tw...
  • Page 69 www.colormetrics.com.tw...

Table of Contents