Using the Control Panel
Interface Setup Mode
The following items can be set in the Interface Setup mode through the Control Panel: INTERFACE, DATA
LENGTH, BAUD RATE, PARITY, PROTOCOL and SIGNAL POLARITY.
You can select and change the desired item according to the status of the FONT/PITCH indicators.
1
Load a sheet of paper ( "'" P.13-18), and
turn the power off.
2
While pressing
1
PITCH) ,turn the power
on to enter the Initial Setup mode.
QUIET indicator, ON LINE indicator and FONT
indicators will be blinking.
The current settings will be printed automatically.
Item
3
Press and release
1
FONT
1
to select the
item.
Each time you press (FONT
1 ,
you will advance
to the next item. Select the desired item according
to the status of the FONT indicators
(on, off, blinking).
4
Press and release
1
PITCH) to set the item's
status.
The item's status will change each time you press
(PITCH
I.
See the table below to verify desired
status.
To change additional settings, repeat steps 3 and
4.
Setting
FONT
PITCH indicators (Press (PITCH I)
indicators
(Press
0
0
0
•
IFONT~
INTERFACE
0
•
AUTO
PARALLEL'
DATA LENGTH
•
0
8 bit'
7 bit
BAUD RATE
• •
300
600
PARITY
,"
NONE'
IGNORE
0
•
PROTOCOL
"
0
DTR'
XON/XOFF
SIGNAL
' .
MARK'
SPACE
•
POLARITY
FONTIPITCH indicators condition:
• =Iight is lit
0
=Iight is out
.. =Iight is blinking
5
Press ( LOAD/PARK Ito exit the Interface
Setup mode.
FONT indicators will go off and the current
conditions will print.
,"
,',
'"'
•
0
• •
0
•
•
0
• •
SERIAL
-
-
-
-
-
-
-
-
-
1,200
2,400
4,800
9,600'
19,200
ODD
EVEN
-
-
-
-
-
-
-
-
-
-
-
-
, =factory setting
Note:
• To return all current settings to the factory
settings, follow the steps below.
1. While pressing (PITCH I , turn the power on,
then release.
2. Press (TEAR OFFI.
3. Press (LOAD/PARK Ito exit the Interface
Setup mode.
c:
!!!.