Central Processing Unit (CPU)

CPU Installation

1. Unlock the socket by pressing
the lever sideways then lifting
it up to a 90°-100° angle. See
Figure 1.
2. Position the CPU above the
socket such that its notched
or marked corner matches the
socket corner near the end of
the lever, while making sure
that the CPU is parallel to the
socket. See Figure 2.
3. Carefuly insert the CPU into
the socket until it fits in place.
4. When the CPU is in place,
press it firmly on the socket
while you push down the
socket lever to secure the
CPU. The lever clicks on the
socket indicating that it is
locked.
IMPORTANT
The CPU fits only in one orientation. Do not force the CPU
into the socket to prevent bending the pins and damaging
the CPU. If the CPU does not fit completely, check its
orientation or check for bent pins.