This Leitch product is warranted against defects in materials and workmanship for a period of one year from the date of invoice. During the warranty period, Leitch will, at its option, either repair or replace products which prove to be defective.
Page 3
(normal blow, time delay, etc.) are to be used for replacement. Caution This add on device, model DEC-6002, is intended to be installed in equipment in the field, by the user, in the manufacturer’s defined operator access area. Check the...
1. General Description. The Genesis DEC-6002 eurocard module is a precision adaptive comb filter decoder for use in any application requiring translation from the analogue composite format to the digital component format. All processing is carried out in the digital domain to full broadcast quality, maintaining 10 bit accuracy from input to output.
Page 6
Video Gain 6002 Chroma Gain Black Level NTSC Hue Multi Use Hex Switch Default = 0 Remote/Local VBI blanked/VBI passed EDH off / EDH on No Pedestal / Pedestal 525 / 625 PAL M & N / PAL I & NTSC Coherent / Non-Coherent Manual / Auto Detect Store...
Page 7
LK7 LK8 SW5 (not fitted on Issue A and B PCB’s) Note: LK5-LK9 Select PSU options A-B = External Rails B-C = Leitch Rails IC 7 IC 34 Document Number: DEC-6002UM2.doc Issue 2 24th March 1998...
2. Installation Rearconnectors that cannot be used in the FR-6002 will be marked as being so. When used in a FR-6004 the rearconnector interconnections are as shown in the manual. When used in a FR-6002 or FR-6001 chassis the rearconnector is mounted horizontally.
Page 9
Leitch chassis. When B-C is shorted together on all these links the normal +6.5 and -7.5V rails are used.
Page 10
Within SW2, switches 5 and 6 select the different modes of decoding adaptation available from the DEC-6002 card. Switch 5 acts as the least significant bit and switch 6 as the most significant bit. So 00 (off,off) is decoding mode 0 and 10 (on,off) is decoding method 2.
Page 11
Adaption modes 1 and 2 offer intermediate levels of adaption. The selection between the decoding modes is a subjective issue and will be largely dependent on the demands of the application. Switch no 4: Set this switch on to kill TRS on the output when there is no input present.
Page 12
Hex Switch: When the hex switch is at zero, all the pot functions are inactive and set to their pre-set values. In any other switch setting (1 to F), the pots are active. The function of the USER led (see diagram page 2)is also controlled by the HEX switch.