FIBARO FIB_FGSS-101 Quick Start Manual page 6

Smoke detector
Table of Contents

Advertisement

Switching to a constant current powering mode:
1. Exclude a sensor from the Z-Wave network.
2. Disconnect the battery.
3. Install the constant power connecting terminal, observing the diagram 2.
4. Connect a constant current power source (12 / 24 VDC) to +12 and GND terminals observing wiring
diagram 1.
5. Include Fibaro Smoke Sensor into the Z-Wave network.
Installation:
1. Include the device into the Z-Wave network (see p.I). Note the inclusion process may be performed
ONLY in direct range of the main controller.
2. If the sensor is to be VDC powered, drill holes in sensor's holder. Note the sensor may be connected
to a wired alarm system controller or fire prevention system.
3. Install the sensor's holder in desired location.
4. If the sensor is to be VDC powered, connect wires observing diagram 3.
5. If the sensor is to be connected to an alarm system or fire prevention system, connect it observing to
diagram 4.
(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 6

Advertisement

Table of Contents
loading

Table of Contents