FIBARO FIB_FGSS-101 Quick Start Manual page 11

Smoke detector
Table of Contents

Advertisement

Temperature measurement compensation (Parameter Number 73, Parameter Size 2) temperature value to
be added to or deducted from the current measured temperature
Value
Description
64536 — 1000
Z-Wave range test interval (Parameter Number 80, Parameter Size 1) Time period between the consecutive
Z-Wave network range tests
Value
0 — 17 0 – Z-Wave network range test inactive (Default 1)
Temperature alarm threshold (Parameter Number 81, Parameter Size 1) Temperature value, above which
the temperature alarm is sent
Value
Description
0
0 – temperature alarm inactive
2 — 100 (Default 54)
Smoke Sensor sensitivity (Parameter Number 82, Parameter Size 1) There are 3 levels of sensitivity to
smoke presence. Level 1 means the highest sensitivity.
Value
Description
1
HIGH Sensitivity
2
MEDIUM Sensitivity (Default)
3
LOW Sensitivity
Black Box sensitivity level (Parameter Number 83, Parameter Size 1) Parameter specifies temperature and
smoke level after which the Black Box starts recording them
Value
Description
1
HIGH Sensitivity
2
MEDIUM Sensitivity
3
LOW Sensitivity
(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 11