FIBARO FIB_FGSS-101 Quick Start Manual page 10

Smoke detector
Table of Contents

Advertisement

Type of alarm frame sent to 1-st Association Group devices (smoke alarm) (Parameter
Number 5, Parameter Size 1) choose a command class used in 1-st Association Group
Value
129
0 (-127) - ALARM SENSOR (SMOKE) command frame
127
255 (127) - BASIC_SET command frame (Default)
Forced dimming level sent to 1-st association group devices (Parameter Number 7, Parameter Size 1)
Forced level of dimming / opening dimmers, roller blinds etc. devices at sending turn on / open / change
level commands to 1-st Association Group's devices.
Value
1 — 99 99 means turning on the device with the last remembered status
Temperature report interval (Parameter Number 10, Parameter Size 2) Time interval between consecutive
temperature reports
Value
Description
0 — 17280 0 (Reports inactive) (Default 0)
Temperature report hysteresis (Parameter Number 12, Parameter Size 1) temperature change, resulting in
a temperature report
Value
0 — 100 0 - temperature change reporting inactive (Default 20)
Alarm broadcast (Parameter Number 13, Parameter Size 1) defines the broadcast alarm setting (alarm to all
devices in direct range)
Value
0
broadcast inactive (Default)
smoke alarm broadcast (1-st Association Group) active; tamper alarm broadcast (2-nd
1
Association Group) inactive
smoke alarm broadcast (1-st Association Group) inactive; tamper alarm broadcast (2-nd
2
Association Group) active
smoke alarm broadcast active (1-st association group); tamper alarm broadcast (2-nd
3
association group) active
(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 10