MTU 20V4000L33F Operating Instructions Manual page 132

Hide thumbs Also See for 20V4000L33F:
Table of Contents

Advertisement

3.
Remove locknut (1).
4.
Remove filter cover (3) with washer (2).
5.
Carefully lift out fine filter (6).
6.
Carefully lift out coalescence filter (5).
7.
Clean sealing faces and inside of housing.
8.
Check condition of gaskets on new fine fil-
ter and new coalescence filter.
Note:
The fine filter (6) must be installed in the
correct position in the housing.
9.
Place fine filter (6) in housing, ensuring it is
straight.
Note:
The coalescence filter (5) must be installed
in the correct position in the housing.
10.
Place coalescence filter (5) in housing, en-
suring it is straight.
11.
Fit filter cover (3), ensuring it is positioned
correctly.
12.
Screw on washer (2) with new locknut (1) and tighten to specified tightening torque with torque wrench.
Name
Locknut
13.
Fit housing cover (1).
14.
Fit clamp (2) neatly and tighten to specified torque using a torque wrench.
Name
Clamp
132 | Task Description | MS150108/02E 2015-03
Size
Type
Tightening torque
Size
Type
Tightening torque
Lubricant
Value/Standard
15 Nm
Lubricant
Value/Standard
5 Nm