Table of Contents FCC RADIO FREQUENCY INTERFERENCE STATEMENT ..4 WARRANTY ....................4 ABOUT THE MINIMC ................4 INSTALLING THE MINIMC ................6 HARDWARE MOUNTING ..............7 POWERING THE MINIMC..............8 LED OPERATION ....................9 SPECIFICATIONS ................. 11 FIBER OPTIC CLEANING GUIDELINES ........12 ELECTROSTATIC DISCHARGE PRECAUTIONS ......
FCC RADIO FREQUENCY INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B computing device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment.
Page 5
Products of other manufacturers sold by B&B Electronics Manufacturing Company are not subject to any warranty or indemnity offered by B&B Electronics Manufacturing Company, but may be subject to the warranties of the other manufacturers. Notwithstanding the foregoing, under no circumstances shall B&B Electronics Manufacturing Company have any warranty obligations or any other liability for: (i) any defects resulting from wear and tear, accident, improper use by the buyer or use by any third party except in accordance with the written instructions or advice of the B&B...
ABOUT THE MINIMC Part Numbers: 855-10622-RX, 855-10622-TX 855-10623-RX, 855-10623-TX 855-10641-RX, 855-10641-TX The above part numbers must be installed in pairs. As a pair, the units provide secure data to be passed in one direction only. The MiniMc provides a single conversion between 10/100 Base- T twisted pair and 100 Base-SX/FX fiber.
HARDWARE MOUNTING The IE-MiniMc can be mounted on a DIN rail or using wall mount brackets (shown below). DIN rail clips (part number 806-39105) and wall mount brackets (part number 895-39229) are available for purchase through a B&B Electronics Distributor. DIN Rail Clips The MiniMc can be mounted with two DIN Rail clips, a...
NOTE The DIN clips are designed for use on a DIN-35 rail. POWERING THE MINIMC The MiniMc includes multiple powering options: A country-specific, high-reliability AC power adapter • (included) IE-PowerTray/18 for Rack Mounting • USB power cable •...
LED OPERATION Each MiniMc includes two LEDs, located on the RJ-45 connector. LED functions are as follows for the TX Unit: FX LNK/ACT Glows green when a link is established on the FX (fiber) port; blinks green when activity is detected on the fiber port.
Page 10
Each MiniMc includes two LEDs, located on the RJ-45 connector. LED functions are as follows for the RX Unit: FX LNK/ACT Glows green when a link is established on the FX (fiber) port; blinks green when activity is detected on the fiber port.
SPECIFICATIONS Ethernet Connections • 10/100 BaseT • Auto Negotiation • AutoCross • Flow Control • 1916 MTU • Full Line-Rate Forwarding AC Wall Adapter 100 to 240 ±10% VAC input, 5 VDC output, 2A max. Operating Temperature +14°F to +122°F (-10C° to +50°C) Storage Temperature -31°C to +167°...
FIBER OPTIC CLEANING GUIDELINES Fiber Optic transmitters and receivers are extremely susceptible to contamination by particles of dirt or dust, which can obstruct the optic path and cause performance degradation. Good system performance requires clean optics and connector ferrules. 1. Use fiber patch cords (or connectors, if you terminate your own fiber) only from a reputable supplier;...
ELECTROSTATIC DISCHARGE PRECAUTIONS Electrostatic discharge (ESD) can cause damage to any product, add-in modules or standalone units, containing electronic components. Always observe following precautions when installing or handling these kinds of products 1. Do not remove unit from its protective packaging until ready to install.
SAFETY CERTIFICATIONS UL/CUL: Listed Safety Information Technology Equipment, including Electrical Business Equipment. The products described herein comply with the Council Directive on Electromagnetic Compatibility (2004/108/EC) and the Council Directive on Electrical Equipment Designed for use within Certain Voltage Limits (2006/95/EC). Certified to Safety of Information Technology Equipment, Including Electrical Business Equipment.