This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile
home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating
plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements locaux
le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque signalétique. Cet
appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result
in serious injury, death, or property damage.
— Do not store or use gasoline or other flammable vapors
and liquids in the vicinity of this or any other appliance.
— WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire
department.
— Installation and service must be performed by a quali-
fied installer, service agency or the gas supplier.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
INSTALLATEUR: Laissez cette notice avec l'appareil.
CONSOMMATEUR: Conservez cette notice pour consul-
tation ultérieure.
Direct-Vent
Epic™
C
US
Report # 14-161

INSTALLATION AND OPERATION

MODEL
EPIC33/40
The Epic™ Gas Stove is factory equipped for 40,000 BTU input and can be con-
verted to 33,000 using a smaller orifice (provided in optional orifice kit P/N H5924).
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité pour-
rait d'entraîner des blessures graves, la mort ou des
dommages matériels.
— Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
— QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où vous
trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de gaz
depuis un voisin. Suivez les instructions du fournis-
seur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
— L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifié ou
par le fournisseur de gaz.
P900110-00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EPIC33 and is the answer not in the manual?

Questions and answers

Summary of Contents for IronStrike EPIC33

  • Page 1: Installation And Operation

    Numéro de la pièce 900182-00. EPIC33/40 The Epic™ Gas Stove is factory equipped for 40,000 BTU input and can be con- verted to 33,000 using a smaller orifice (provided in optional orifice kit P/N H5924).
  • Page 2 SAFETY AND YOUR GAS STOVE See attached color flyer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS. A barrier designed to reduce the risk of burns from the hot viewing glass is pro- vided with this appliance and shall be installed for the protection of children and other at-risk individuals.
  • Page 3: Safety And Your Gas Stove

    La sécurité et votre Safety and Your Seguridad y su poêles au gaz Gas Stove chimenea All parts of your Toutes les parties de ¡Todas las partes de la votre poêles au gaz IHP IHP gas stove get chimenea IHP se ponen deviennent EXTRÊMEMENT EXTREMELY HOT! MUY CALIENTES!
  • Page 4: Table Of Contents

    CONGRATULATIONS! Horizontal Vent Installation ........18 Vertical Vent Installation ........19 When you purchased your new gas stove, you joined the ranks Flue Restrictors ............20 of thousands of individuals whose answer to their home heat- Horizontal Terminations ......... 21 ing needs reflects their concern for aesthetics, efficiency and Vertical Terminations ..........
  • Page 5: Important Safety Information

    IMPORTANT SAFETY INFORMATION Important Safety Informa- Información importante de L’information de sûreté tion seguridad importante 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1. ADVERTENCIA: No opere el artefacto con el with the glass front removed, cracked si le panneau frontal en verre n’est pas en frente de vidrio quitado, agrietado o roto.
  • Page 6: Homeowner - Attaching Safety In Operation Warnings

    Cat. No. H8024 Replacement Label Kit vous plaît contactez IHP ou votre revendeur le plus Juego de etiquetas de repuesto - Nº de cat. H8024 proche pour recevoir IHP étiquettes d’instructions IronStrike.us.com de sécurité supplémentaires gratuitement. Étiquettes de remplacement, n° cat. H8024 IronStrike.us.com Note: English is red text on clear label.
  • Page 7: Installer - Attaching Safety In Operation Warnings

    IHP étiquettes d’instructions de sécurité supplémentaires gratuitement. Juego de etiquetas de repuesto - Nº de cat. H8024 IronStrike.us.com Étiquettes de remplacement, n° cat. H8024 Note: English is red text on clear label. French and IronStrike.us.com Spanish are white text on black label.
  • Page 8: Appliance Installation, Service, And Maintenance Notices

    Appliance Installation, Service, and If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this Maintenance Notices appliance. Si l’écran est endommagé, il doit être remplacé par WARNING: Improper installation, adjustment, alteration, celui fournit par le fabricant de cet appareil. service or maintenance can cause injury or property damage.
  • Page 9: Important Safety And Warning Information

     Plated surfaces must be cleaned with glass cleaner and a clean IMPORTANT SAFETY AND WARNING soft cloth before firing the first time or fingerprints will remain INFORMATION permanently. NEVER use brass polish to clean plated surfaces, this will remove the plating!!!  C AUTION: Hot while in operation.
  • Page 10: Orifice Size/Altitude Adjustment

    It has met all necessary ANSI Standards and is fully certified for installa- ORIFICE SIZE/ALTITUDE ADJUSTMENT tion in any community. If there are any questions or if you need further substantiation either write to or call your IHP dealer. If you have further questions, please contact IHP.
  • Page 11: Pre-Installation

    1 Installation and Operation Manual Trim Kits Gold, Brushed Nickel, or Black Nickel Trim Kit * Other approved chimney brand is Simpson Dura-Vent DV-GS. Epic™ 33 (EPIC33) Epic™ 40 (EPIC40) RATINGS NATURAL GAS LP GAS...
  • Page 12: Preparing Your Epic Stove For Installation

    Dimensions Preparing Your Epic™ Stove For Installation Read all instructions before beginning your installation. If instructions The gas line attaches to the gas valve at the lower left corner at the have not been read carefully, your installation could void your warranty back of the stove.
  • Page 13: Clearances To Combustibles

    Clearances to Combustibles Alcove dimensions Minimum clearances to combustible materials in inches (millimeters): The minimum width between the alcove side walls is 48” (1219mm). The minimum height of the alcove is 69” (753mm) and the maximum depth is 48” (1219mm). Parallel Installation Back Wall 24-1/2”...
  • Page 14: Firebox Setup

    Firebox Setup Burner Pan Diagram Log Stands Gas Ports Air Deflector Secondary Air Holes Figure 7 Completed Firebox Setup Do not cover any secondary air holes or gas ports (see Burner To ensure a proper burn leave a 1” space free of any embers (volcanic Pan Diagram above) behind this line.
  • Page 15: Firebox Liner Installation

    Firebox Liner Kit Installation 4. Using the included screws, install the firebox liner retaining brackets (D) above the left and right firebox liner panels (B and C). CAUTION: The firebox liner panels are required for your appli- ance to function correctly and safely. Packaging List: Rear brick panel (A), left brick panel (B), right brick panel (C), retaining brackets (D) - in flue restrictor bag 1.
  • Page 16: Log Set And Ember Installation

    Log Set and Ember Installation If logs are not installed according to the log installation instruc- tions, flame impingement and improper combustion could occur and result in soot and/or excessive production of carbon monoxide (CO), a colorless, odorless, toxic gas. The size and position of the log set is critical to achieve a safe, reliable and attractive flame pattern.
  • Page 17: Vent Installation

    Minimum Components for Horizontal Installation: Horizontal Termination Kit which includes: • 1 6-5/8”x 6” Black Pipe • 1 Riser Vent Terminal • 1 Wall Penetration Heat Shield (Wall Thimble) (2 pcs) • 1 Decorative Wall Trim (black) • 1 Tube Mill-Pac •...
  • Page 18: Vent Parts List

    Vent Parts List Horizontal Vent Installation Secure Vent ® direct-vent pipe may be used with the Epic™ gas stove. Venting terminals may not be recessed into a wall or siding. Please see the lists below to verify the components available from each direct-vent pipe manufacturer.
  • Page 19: Vertical Vent Installation

    Vertical Vent Installation Important Notes Vertical Termination Cap Storm Collar 1. All vertically terminated vent installations use 6-5/8”x 4” Secure Vent pipe*. ® Flashing 2. If the vent passes through a ceiling or floor, a firestop - Simpson Roof - Maintain #963 or IHP #SV4BF - is required.
  • Page 20: Flue Restrictors

    Flue Restrictors have a proper burner flame appearance. If the proper flame appearance cannot be achieved, the flue restrictor may need to be changed to a dif- ferent position (A,B,C or D). See the following guidelines to determine if The flue restrictor settings shown in Figures 25 and 26 are for typical installations and may need to be adjusted from standard to take into you need to readjust the flue restrictors.
  • Page 21: Horizontal Terminations

    Horizontal Terminations Vertical Terminations The shaded areas in the diagram below show all allowable combinations The diagram below shows all allowable combinations of straight vertical of vent configurations with horizontal terminations. Horizontal sections and offset to vertical vent configurations with vertical terminations. The of pipe require 1/4”...
  • Page 22: Horizontal Vent Termination Locations

    Exterior Horizontal Vent Termination Clearance Requirements * See Item D in the Text Below. Center Line Exterior Wall Inside of Termination Corner Detail *18” Horizontal Termination 18” Ventilated Soffit Inside Corner = 9" in U.S. = 12" in Canada DETAIL D 3 ft.
  • Page 23: Gas Line Installation

    Gas Line Installation Also check the orifice size on the label on the igniter bracket. It must be the correct size for the fuel and altitude. This stove must be connected to the gas line in accordance with local codes and/or the National Fuel Gas Code, ANSI Z223.1 (In Canada, the Do not run propane tank dry.
  • Page 24: Operating Instructions

    Operating Instructions WHAT TO DO IF YOU SMELL GAS: Pre-Lighting Checklist: • DO NOT try to light the appliance. • DO NOT touch any electric switch; do not use any phone in Be sure to check these items before the initial lighting of the your building.
  • Page 25: Flame Color And Behavior

    10. After pilot is lit, turn gas control counterclockwise “ON.” Knob can only be turned “ON” if the knob has popped Control Panel out. 11. To turn burner on, turn “ON/OFF” rocker switch to “ON” or GAS CONTROL Gas Control set the thermostat to the desired temperature above room FLAME HEIGHT ON/OFF...
  • Page 26: Air Shutter Adjustment

    Quiet Operation Pilot Flame Appearance As the Epic gas stove is burning, a number of normal operational sounds may be heard. The flow of gas through the gas valve and orifice may make a rushing or whistling noise. If this noise is objectionable, it can be reduced by turning down the flame.
  • Page 27: Operating Options

    Operating Options Thermostat Wire Wire Size Maximum Length Your stove comes equipped with an “On/Off” rocker switch used to turn the burner on and off while the pilot light is on. The switch is a round 12 Gage 100 Feet rocker switch located behind the main control panel door.
  • Page 28: Maintenance And Servicing

    The viewing glass should be cleaned periodically (see Glass Door MAINTENANCE AND SERVICING Cleaning and Maintenance). Should repairs or maintenance of the stove require the disassem- WARNING bly of the vent/air intake system, the reassembly and resealing should be completed by a qualified service technician and follow the instructions on Page 17 of this manual.
  • Page 29: Glass Door Cleaning And Maintenance

    Glass Door Glass Door Cleaning and Maintenance Cleaning: Do not remove or clean the glass door when hot. When WARNING cool, the glass may be cleaned with a clean, soft cloth and glass cleaner. For cleaning white condensation from the interior glass use a gas stove •...
  • Page 30: Replacing A Damaged Barrier

    Replacing the Damaged Barrier: Barrier • If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. • For use with barrier Part No. J7490. Follow installation instructions. To remove the damaged barrier 1. Shut off the main burner using the rocker switch. 2.
  • Page 31: Fuel Conversion

    Fuel Conversion 10. Mark and unplug the remaining fan wire. Remove the three screws securing the fan and set aside. Converting the stove between natural gas (NG) and propane (LP) can be 11. Remove the cassette assembly by carefully pulling the top cassette accomplished by either changing the cassette (valve and pilot assembly) plate downward, guiding the pilot assembly out of the firebox, down or installing a conversion kit (regulator, burner orifice and repositioning...
  • Page 32: Troubleshooting

    TROUBLESHOOTING NOTE: When troubleshooting the gas control system, be sure the external gas shut off valve, located at the gas supply inlet is in the “ON” position. IMPORTANT: Call your gas supplier or plumber for additional help with any gas control problem. Valve system troubleshooting should only be accomplished by a qualified service technician.
  • Page 33: Wire Harness Diagram

    Wire Harness Diagram CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. ATTENTION: Au moment de l'entretien des commandes, étiquetez tous les fils avant de les débrancher. Des erreurs de cáblage peuvent entraîner un fonctionnement inadéquat et dangereux. Blower Ring Lug Crimp Female Spade 1/4”...
  • Page 34: Replacement Parts

    Contact an IHP dealer to obtain any of these parts. Please contact IHP REPLACEMENT PARTS - Epic™ 33/40 (EPIC33/40) for the phone number of your nearest IHP dealer. Diagram No. Part No. Description WARNING H3102 Front Door Never use substitute materials. Use of non-approved...
  • Page 35 REPLACEMENT PARTS DIAGRAMS - EPIC™ 33/40 (EPIC33/40) NO. DESCRIPTION NO. DESCRIPTION NO. DESCRIPTION FRONT DOOR 12 SIDE DOOR 23 SMALL RELIEF DOOR RIGHT BURNER SUPPORT 13 SIDE DOOR 24 SPRING, RELIEF DOOR LEFT BURNER SUPPORT 14 SNAP SWITCH 25 WASHER, RELIEF DOOR...
  • Page 36: Replacement Parts

    REPLACEMENT PARTS DIAGRAMS - EPIC™ 33/40 (EPIC33/40) NO. DESCRIPTION NO. DESCRIPTION NO. DESCRIPTION 55 AC POWER PLUG 33 FLAME CONTROL EXTENSION 44 BLOWER 56 PEDESTAL BACK 34 PILOT CONTROL EXTENSION 45 SLIDER WASHER 57 THERMO. OUTLET BRACKET 35 VALVE ASSY.
  • Page 37: Accessories

    ACCESSORIES Gas Conversion Kits Product Reference Information Cat.# Model Ship. Wt. Ship. Volume F2325 EPIC33/40-DVS-C 211 lb. 25.0 cu. ft. Cat. No. Model Description 75355 EPIC-CK-LP to NG Conversion Kit LP to NG (ref. form #775235M) 75352 EPIC-CK-NG to LP Conversion Kit NG to LP (ref.
  • Page 38 ACCESSORIES (continued) Cost Effective Solution • Simple On/Off operation • Works with millivolt and low voltage electronic ignition controls Flame and Heat modulation Kit includes: • Includes solenoid for SIT millivolt valves Remote and Receiver • Thermostatic, manual or up to 9 hour Count- Thermostatic or Manual modes down Timer modes G-Fire Remote, Simple On/Off...
  • Page 39: Stove Labels

    SAFETY / LISTING LABEL MODEL SERIAL NO. HOMOLOGUÉ FOYER RADIANT PRÉFABRIQUÉ AU GAZ - NE PAS UTILISER AVEC DU COMBUSTIBLE EPIC™ NUMÉRO DE MODÈLE SOLIDE SÉRIE MAY BE INSTALLED IN RESIDENTIAL BEDROOMS AND MANUFACTURED (MOBILE) HOMES. MANUFACTURED BY: CONFORME AU STANDARD ANSI Z21.88-2014/CSA 2.33-2014, UL307B, CSA P.4.1-09, ET CAN/CGA-2.17-M91 (R2009). INNOVATIVE HEARTH PRODUCTS CET APPAREIL DOIT ÊTRE INSTALLÉ...
  • Page 40: Shutdown Procedure

    LIGHTING LABEL FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. CAUTION: HOT WHILE IN OPERATION. DO NOT TOUCH. KEEP CHILDREN, FURNITURE, GASOLINE AND OTHER LIQUIDS WITH FLAMMABLE VAPORS AWAY. NEVER OPERATE UNIT WITH GLASS DOOR OFF OR ATTEMPT TO OPEN THE DOOR WHILE HOT.
  • Page 41: Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") 20 Year Limited Warranty warrants your IronStrike™ brand gas fireplace or insert ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the 20 Year Limited Warranty. Ceramic glass carries the 20 Year Limited Warranty against thermal breakage only.
  • Page 42: Product Reference Information

    Innovative Hearth Products dealer. Parts will be shipped at prevailing prices at time of order. 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 visit us at IronStrike.us.com Model Number _____________________________________________________ Serial Number _____________________________________________________ Date Installed ______________________________________________________ Your Dealer's Name _________________________________________________...