Electrical Adjustments
Group
No.
Item
0
Hi-Land SW
1
Not used
2
ANZEN FAN Control Fix SW
142
Fan Parameter Setting
0
FAN_TEMP_A_WARNING
1
FAN_TEMP_B_WARNING
2
FAN_TEMP_C_WARNING
3
Not used
4
Not used
5
Control Switch All
6
FAN A Manual Out
7
FAN B Manual Out
8
FAN C Manual Out
9
FAN D1 Manual Out
10
FAN D2 Manual Out
11
FAN EManual Out
12
Temp Source Range High
13
Temp Source Range Low
14
Temp Fan-Out Range High
15
Temp Fan-Out Range Low
16
Not used
17
Not used
18
Not used
19
Not used
20
Presss Source Range Low
21
Presss Source Range High
22
Press FanAdd Range High
23
Press FanAdd Range Low
24
Ceil-Add
149
PJ Filter Reset Times
0
FILTER_CLR_CNT
150
Shippment Setting
0
Shippment Setting
160
Shootout
0
Switch
170
Smoke Resist Fan
0
Smoke Fan1 Speed Monitor
1
Smoke Fan2 Speed Monitor
2
Smoke Fan Speed Control
3
Smoke Fan Speed Setting
4
Smoke fan Setting Speed Monitor
5
Smoke Fan Speed Mini. Duty Value
6
Smoke Fan Speed Max. Duty Value
7
Smoke Fan Speed Min. Temp.
8
Smoke Fan Speed Max. Temp.
9
Smoke Box Time Counter Reset Times
10
Smoke Box use time
11
Smoke Box Version
171
Smoke Box Fan: Calibration
0
Execute calibration of Fan Speed
1
Smoke Fan1: result Offset
2
Smoke Fan1: result Min.
3
Smoke Fan1: result Max.
4
Smoke Fan2: result Offset
5
Smoke Fan2: result Min.
6
Smoke Fan2: result Max.
7
Smoke Fan Calibration OK Times
8
Air Pressure at Smoke Filter Calibration
180
DDC Setting
0
HDCP EDID Data Setting
190
Mecha Shutter
0
Warming up option
200
Panel Adjustment PC [Lamp ALL]
0
A03(IC571)V1G
1
A01(IC571)V1R
2
A05(IC571)V1B
3
A04(IC571)V2G
Function
0:Normal Mode1: High-land Mode (Fan max speed continuously)
Not used
0:Normal 1:Normal Min2:Normal Max3:Eco Min4:Eco Max
Temperature A to judge Abnormal Temp. (memorized) Outside
Temperature B to judge Abnormal Temp. (momorized) on Panel
Voltage C to judge Abnormal Temp. (momorized) arround Panel
0:Auto-control all of FANs 1: Manual Control all of FANs
Fan voltage in the manual mode
Voltage= Value/100
Effective FAN_CONTROL_SW=1
Step in 10, 0.1V
High and Low control limit value at Temp. sensor A
Temp. =Value/10
High and Low Fan voltage value at Temp. sensor A
Voltage = Value/100
High and Low control limit value at Atmosphere Sensor
Note: Low is Fan add Max point accually
High and Low Fan Voltage value at Atmosphere Sensor
Voltage = Value/100
Additional Voltage at Ceiling use Voltage = Value/100
Reset times of the airfilter timer counter
All of settings are set to default when the value changes to 10
0:Off, 1:On
Fan speed 1monitor of Smoke resister
Fan speed 2monitor of Smoke resister
Set speed for Smoke resister 0:Normal / 1:MAX fixed / 2:USER(setting
enable on 170-3)
Set speed of user setting for Smoke resister (Effective only 170-2 is
2 (USER)
Monitor at current setting
Display Duty value at minimum temp. for Auto-Fan Control
Display Duty value at maximum temp. for Auto-Fan Control
Sets minimum temp. for Auto-Fan Control
Sets maximum temp. for Auto-Fan Control
Reset times of the Smoke Box time counter
Accuurated use time of the Smoke Box
"9999" upper 2 digits for Main version, lower for Sub version
1: Execute Calibration, 2: Complete, -1: Error
Smoke Fan1: result of cloggled filter calibration, Offset value
Smoke Fan1: result of cloggled filter calibration, Min. Fan Speed
Smoke Fan1: result of cloggled filter calibration, Max. Fan Speed
Smoke Fan2: result of cloggled filter calibration, Offset value
Smoke Fan2: result of cloggled filter calibration, Min. Fan Speed
Smoke Fan2: result of cloggled filter calibration, Max. Fan Speed
Succeed times of the Smoke Box Calibration
Air Pressure at Smoke Filter Calibration
0:EDID Data for DVI / 1:EDID Data for HDCP
0:Warming up Enable1:Warming up Disable
DAC Video Center G L (IC571 16pin)
DAC Video Center R L (IC571 14pin)
DAC Video Center B L (IC571 18pin)
DAC Video Center G H (IC571 17pin)
- 50 -
Range
Initial Value
0 ~ 1
0
--
43
60
55
--
--
0 / 1
0
0~2000
0~2000
0~2000
0~2000
0~2000
0~2000
30 ~ 100
41
0 ~ 100
27
0~2000
1400
0~2000
0
--
--
--
--
0~1024
515
0~1024
745
0~255
35
0~255
0
0~2000
0
0 ~ 10
0
0 / 1
0
---
---
---
---
0 ~ 2
0
0 ~ 50
20
--
--
20
50
0 ~ 99
27
(Not momorized)
0 ~ 99
40
(Not momorized)
-1 ~ 2
0
0 / 1
0
0 / 1
0
XGA[SXGA]
0 ~ 255
84 [80]
0 ~ 255
84 [80]
0 ~ 255
84 [80]
0 ~ 255
144 [143]