Sharp LC-45GD6U Service Manual page 17

Hide thumbs Also See for LC-45GD6U:
Table of Contents

Advertisement

21.Remove the connectors from PWBs.
22.Remove the AV PWB.
22-1. Remove the 6 lock screws 20-1 and detach the AV PWB Unit.
22-2. Remove the 5 lock screws 20-2 and detach the AV Cover R.
23.Remove the 4 lock screws 21 and detach the DC/DC2 PWB.
24.Remove the 2 lock screws 22 and detach the 1 Bit Amp.
25.Remove the 4 lock screws 23 and detach the DC/DC1 PWB.
26.Remove the 6 lock screws 24 and detach the AC-INLET PWB.
27.Remove the 2 lock screws 25 and detach the TOP LCD CONTROLLER PWB.
28.Remove the 6 lock screws 26 and detach the BOTTOM LCD CONTROLLER PWB.
29.Remove the 3 lock screws 27 and detach the SP-T PWB.
30.Remove the 8 lock screws 28 and detach the POWER PWB.
31.Remove the 5 lock screws 29 and detach the INVERTER-1 PWB.
32.Remove the 5 lock screws 30 and detach the INVERTER-2 PWB.
33.Remove the 5 lock screws 31 and detach the INVERTER-3 PWB.
34.Remove the 5 lock screws 32 and detach the INVERTER-4 PWB.
20-2
20-2
AV Cover R
AV PWB
TOP LCD CONTROLLER PWB
20-1
31
22
1 Bit
Amp.
INVERTER-3 PWB
INVERTER-4 PWB
32
SP-T PWB
27
BOTTOM LCD
CONTROLLER PWB
21
23
25
DC/DC2
PWB
26
POWER PWB
28
17
LC-45GD6U
29
DC/DC1
PWB
INVERTER-1 PWB
INVERTER-2 PWB
30
AC-INLET PWB
24
28