Panasonic WH-UD07CE5-A Service Manual page 14

Hide thumbs Also See for WH-UD07CE5-A:
Table of Contents

Advertisement

Item
Power Cord
Thermostat
Protection Device
Item
Performance Test Condition
Operation Range
Internal Pressure Differential
Noise Level
Dimension
Net Weight
Refrigerant Pipe Diameter
Water Pipe Diameter
Water Drain Hose Inner Diameter
Pump
Hot Water Coil
Pressure Relief Valve Water Circuit
Flow Switch
Protection Device
Expansion Vessel
Capacity of Integrated Electric Heater
Note:
• Heating capacities are based on outdoor air temperature of 7°C Dry Bulb (44.6°F Dry Bulb), 6°C Wet Bulb (42.8°F Wet Bulb) with
controlled indoor water inlet temperature of 30°C and water outlet temperature of 35°C.
• Specification are subjected to change without prior notice for further improvement.
Number of core
Length
Outdoor Ambient
Water Outlet
Height
Width
Depth
Liquid
Gas
Inlet
Outlet
Motor Type
No. of Speed
Input Power
Type
No. of Plates
Size (H x W x L)
Water Flow Rate
Volume
MWP
Unit
m (ft)
Unit
°C
°C
Pa
dB (A)
Power Level dB
mm (inch)
mm (inch)
mm (inch)
kg (lbs)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
mm (inch)
W
mm
3
l/min (m
/h)
kPa
A
I
bar
kW
14
-
-
Electronic Control
Electronic Control
Indoor Unit
EUROVENT
-20 ~ 35
25 ~ 55
30200
30
43
892 (35-1/8)
502 (19-3/4)
353 (13-29/32)
49 (108)
9.52 (3/8)
15.88 (5/8)
28 (1-3/32)
28 (1-3/32)
15.00 (19/32)
Capacitor Run Induction Motor (5 μF)
3
190
Brazed Plate
80
130 x 93 x 325
45.9 (2.8)
Open: 190, Close: 183 and below
Magnetic Lead Switch
Residual Current Circuit Breaker (40)
10
1
6.00