19.2. Heating Capacity Table
19.2.1. WH-SDF07C3E5 WH-UD07CE5-A
LWC
Tamb
-15
-7
2
7
25
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
19.2.2. WH-SDF09C3E5 WH-UD09CE5-A
LWC
Tamb
-15
-7
2
7
25
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
19.2.3. WH-SDF12C6E5 WH-UD12CE5-A
LWC
Tamb
-15
-7
2
7
25
HC: Heating Capacity (kW)
IP: Power Input (kW)
LWC: Leaving Water Condenser Temperature (°C)
Tamb: Ambient Temperature (°C)
30
35
HC
IP
HC
IP
4.60
1.87
4.60
2.00
5.15
1.80
5.15
1.94
6.70
1.83
6.55
1.98
7.00
1.43
7.00
1.59
7.00
0.79
7.00
0.93
30
35
HC
IP
HC
IP
6.00
2.55
5.90
2.68
6.10
2.16
5.90
2.36
6.80
1.87
6.70
2.16
9.00
1.93
9.00
2.20
9.00
1.07
9.00
1.27
30
35
HC
IP
HC
IP
9.30
3.50
8.90
3.66
10.40
3.41
10.00
3.70
11.80
3.14
11.40
3.35
12.00
2.14
12.00
2.57
12.00
1.42
12.00
1.70
40
45
HC
IP
HC
IP
4.60
2.19
4.60
2.42
5.08
2.14
5.00
2.38
6.58
2.29
6.60
2.64
7.00
1.77
7.00
2.12
6.40
1.03
6.10
1.17
40
45
HC
IP
HC
IP
5.50
2.82
5.40
3.00
5.85
2.63
5.80
2.90
6.70
2.38
6.60
2.64
9.00
2.45
9.00
2.81
8.40
1.40
8.00
1.59
40
45
HC
IP
HC
IP
8.50
3.83
8.10
3.99
9.60
3.99
9.20
4.28
11.00
3.57
10.60
3.78
12.00
3.00
12.00
3.43
11.80
1.98
11.70
2.27
134
50
55
HC
IP
HC
IP
4.55
2.68
4.50
3.00
4.90
2.47
4.80
2.67
6.30
2.90
6.00
3.16
6.90
2.30
6.80
2.72
5.90
1.33
5.70
1.49
50
55
HC
IP
HC
IP
5.20
3.14
5.00
3.33
5.80
3.06
5.80
3.22
6.30
2.90
6.00
3.16
8.95
3.23
8.90
3.87
7.80
1.81
7.50
2.03
50
55
HC
IP
HC
IP
7.50
4.09
7.00
4.20
8.70
4.30
8.20
4.31
9.80
3.98
9.10
4.18
12.00
3.82
12.00
4.20
11.50
2.53
11.40
2.78