6.6.8. MBS SET

(1) MBS = Main Bang Suppression
(2) It may be Main Bang phenomenon in a center
of the indicator in a short range and can be
suppressed as followings. (In a transmitting)
Adjust it till the noise is suppressed.
Adjust it with optimum.
Adjust it with optimum.
Set it to 0.125NM for distance range.
Menu screen
Move to INIT. SET
Push bottons one after another,
It is displayed additional menu
out of default(settion) menu.
Move to MBS SET,
Select, PPI screen comes up and
displayed number in the middle of
top screen.
Suppress the signal of Main Bang to
the desirable distance.
[ Ref. ] ☞ Adjust Range : 000 ~ 117
Set by adjusted value which has
been completed.
Return to ordinary PPI screen.
: 1 Step Adjust
: 10 Step Adjust
0.125
0.25
CAUTION
※ Above function must be cared
extremely because the collision may
take place due to the objects near by
own vessel are disappeared as such
MBS signal.
※ An error showing, trans-time, program
load and LCD set must not be adjusted
without notice.