INDICATION OF FAULT CONDITIONS

The HF2013DX-A has the following indicationson the front LCD panel:
G2
HV
IA
FAULT
OPR
STBY
WAIT
TEMP
G1MAX
Should a fault condition appear during the tuning or operation of the amplifier the
safetycircuits of HF2013DX-A will react. The amplifier will be turned to STBYmode. After
approx. 5seconds the control circuits will switch the amplifier back to OPR. If the fault repeat 3
times, the control circuits will turn the amplifier to STBY. You must toggle the
switch to reset this fault condition. After the reaction of safety circuits the FAULTLCD will be lit
up for approx. 5 to 10 secdepending on the nature of the fault.
FLASHING LCD SIGNALS:
IP
HV
FAULT
GRID MAX
GRID MAX + HV
HV + IP
In case your HF2013DX-A amplifier is not working correctly, please contactthe manufacturer
or your distributor.
HF2013DX-A HF AMPLIFER INSTRUCTION MANUAL
Measure of the Grid current.
Measure of anode voltage by LCD graph
Measure of anode currency by bar graph
Fault Condition – See RED flashing indicators.
Amplifier in operation mode
Amplifier in standby mode
Heating tube after switching on – Please wait 150sec
Measuring of the tube exhaust temperature
Grid Current exceeded maximum
anode current exceeded
low anode voltage
reflected output exceeded
first grid current exceeded
screen grid current exceeded
maximum load power exceeded
tuning fault, incorrect tuning of the Pi-L output circuit