Download Print this page

Baxi Solo 2 60 RS User Instruction page 2

Wall mounted room sealed gas fired central heating boilers

Advertisement

Natural Gas
Baxi Solo 2 60 RS
G.C.No. 41 077 79
Baxi Solo 2 50 RS
G.C.No. 41 077 78
Baxi Solo 2 40 RS
G.C.No. 41 077 77
Baxi Solo 2 30 RS
G.C.No. 41 077 76
Baxi Limited is one of the leading
manufacturers of domestic heating products in
the UK.
Our first priority is to give a high quality service
to our customers. Quality is built into every
Baxi product - products which fulfil the
demands and needs of customers, offering
choice, efficiency and reliability.
To keep ahead of changing trends, we have
made a commitment to develop new ideas
using the latest technology - with the aim of
continuing to make the products that
customers want to buy.
Everyone who works at Baxi has a
commitment to quality because we know that
satisfied customers mean continued success.
We hope you get a satisfactory service from
Baxi. If not, please let us know.
Baxi is a BS-EN ISO 9001
Accredited Company
Your Baxi Solo is a gas fired, room sealed central heating boiler providing
heating for your home and domestic hot water where required.
OPERATING YOUR SOLO
1
3
IGNITER BUTTON
GAS CONTROL
KNOB
BOILER THERMOSTAT KNOB
"Benchmark" Installation, Commissioning and
Service Record Log Book
Please ensure that your Installer has completed
the Installation and Commissioning sections of
the Log Book, and hands the Log Book over. The
details of the Log Book will be required in the
event of any warranty work. Keep the Log Book in
a safe place and ensure that the relevant sections
are completed at each subsequent regular
service visit.
page 2
Remove lower door panel as
1
shown.
2
2
Turn the boiler thermostat knob
to the '0' position fully anti-
clockwise.
3
Turn on the main gas and
electricity supplies to the
appliance.
4
To light the pilot: Looking
through the pilot viewing window
press the gas control knob fully
inwards and hold. Press in igniter
button and release. Repeat until
pilot ignites. Continue to hold in
gas
approximately 15 seconds
and then release. Pilot should
stay alight.
NOTE: If pilot fails to remain alight or
is extinguished at any time, wait at
least 3 minutes then repeat the
procedure from the start of section "4".
Once the pilot is alight it may be left
on permanently.
5
To light the boiler: Ensure that
all external controls, e.g. room
thermostat, timer, etc. are calling for
heat. Turn boiler thermostat fully
clockwise to high setting. Main burner
will then light.
It is recommended that the boiler
thermostat is used on HIGH setting
in winter and a minimum of n
summer to ensure adequate
domestic hot water.
control