Installation
▶ Re-fit the retaining pin through the valve body.
Fig. 11 Re-fitting the retaining pin
▶ Fit the compression elbow [1] (supplied packed with the boiler)
using thread sealant.
▶ Fit a 22 mm metal discharge pipe [2].
1
2
Fig. 12 Fitting the compression elbow with discharge pipe
5.6

Installing the syphon

DANGER: Danger of fatal accidentdue to poisoning.
▶ If the syphon is not filled with clean water, flue gas
can escape and put people's lives at risk.
▶ Fill the syphon (supplied with the boiler) with clean water.
Fig. 13 Filling the syphon with clean water
8
▶ Connect the syphon [1] to the condensate drain outlet (CDO).
6 720 648 721-007.1TD
Fig. 14 Installing the syphon
[1]
▶ Connect the syphon hose [3] and the rubber sleeve [2] to the syphon
6 720 648 721-008.1TD
Fig. 15 Installing the syphon hose
[1]
[2]
[3]
5.7
▶ Connect the condensate drain pipe to the syphon.
Observe the following regulations:
• The waste water disposal regulations.
• Plastic pipework must be used to drain the condensate, at least until
• The condensate must be able to run into a funnel (or neutralisation
6 720 614 027-06.1TD
The trap is fitted with a bayonet connection. After
pushing [1.] the trap upwards into place, you have to
turn it a ¼ turn anticlockwise [2.] until it locks into
position.
1.
2.
1
Syphon
[1].
1
Syphon
Rubber sleeve
Syphon hose

Connecting the condensate drain pipe

it is delivered to the sewage system.
tank) without restrictions. This prevents condensate from building
up in the boiler. The syphon in the connection kit must no be
permanently connected to the condensate drain pipe. The minimum
distance between the syphon and the condensate drainage pipe is 2
cm [1].
7746800108-13.1TD
2
3
7746800108-14.1TD
6720813174 (2014/09)