Safety Devices; Operation; Prior To Initial Operation; Mains Connection - Elektra Beckum MEGA 700 D Instruction Manual

Hide thumbs Also See for MEGA 700 D:
Table of Contents

Advertisement

meet all conditions necessary for the
proper operation of the electric tool.
Damaged protection devices or parts
must be repaired or replaced by a quali-
fied specialist. Have damaged switches
replaced by a service centre. Do not
operate electric tool if the switch can not
be turned ON or OFF.
Keep handles free of oil and grease.
3.3

Safety devices

Safety valve
The spring-loaded safety valve (19) is
incorporated into the pressure switch.
The safety valve opens if the max. per-
missible pressure is exceeded.

4. Operation

4.1

Prior to initial operation

Filling with pneumatic oil
1.
Remove cup of lubricator (20) and
fill with pneumatic oil to a level
between the two markings.
2.
Replace the lubricator cup.
4.2

Mains connection

B
Danger! High Voltage
Operate machine in dry envi-
ronment only.
Operate machine only on a power
source complying with the following
requirements:
− outlets properly installed, earthed
and tested;
− fuse protection in accordance
with the technical specifications.
Position power cable so it does not
interfere with the work and is not
damaged.
Always check to see that the machine
is switched OFF before plugging in.
B
Check direction of rotation!
Depending
sequence, the motor could turn in the
wrong direction. This can damage the
machine. Therefore the direction of
rotation is to be checked every time
the machine is connected to the
power supply: The pulley of the com-
pressor pump must turn in the direc-
tion indicated by the arrow on the belt
guard.
19
If it turns in the wrong direction, two
phases must be interchanged in the
power cable plug:
1.
Unplug.
2.
Interchange phases with a scre-
wdriver as illustrated:
− Depress switch (21) slightly
− and turn by 180 °.
3.
Plug power cable in again.
Protect
power
aggressive liquids and sharp edges.
Use only extension cables with suffi-
cient lead cross section (see "Techni-
cal Specifications").
20
Do not stop the machine by unplug-
ging, but switch OFF using the ON/
OFF switch.
Unplug after use.
4.3
Generating compressed
air
1.
Connect air hose to compressor.
Depending on the purpose of appli-
cation three outlets are available.
− Air outlet for regulated, filtered,
oil-free compressed air (22).
− Air outlet for regulated, filtered,
lubricated compressed air (23).
− Air outlet for non-regulated, unfil-
tered, oil-free compressed air
(24).
on
the
phase
21
cable
from
heat,
ENGLISH
.
22
A
Danger!
Hazard generated
pressed air containing oil. Use com-
pressed air containing oil only for
applications that require such supply.
Do not operate air tools such as tyre
inflator gauges or paint spray guns
on lubricated air.
An air hose, which has been used for
lubricated air, must not be used for
applications requiring oil-free com-
pressed air.
2.
Start compressor (25) and wait until
the max. tank pressure is reached
(compressor shuts off).
25
The tank pressure is indicated by
the tank pressure gauge (26).
26
27
28
23
24
by
com-
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents