Jp5: Uart Input Clock Speed Selector; Jp1: Rs-422/485 Mode Selector - DeLOCK RS-422/485 Installation Manual

Multiport serial
Table of Contents

Advertisement

3.2.1 JP5: UART Input Clock Speed Selector

UART Input Clock Speed = 1.8432MHZ,
the maximum baud rate is 115.2Kbps
(Default)
UART Input Clock Speed = 14.7456MHZ,
the maximum baud rate is 926.1Kbps. In
this setting, you need go to Windows'
COM port Properties to detect this input
clock automatically and fit this clock
value (see the software setup for more
details)

3.2.2 JP1: RS-422/485 Mode Selector

485
RTS
ECHO
LOOP
Mode Settings for both S1 and S2 (JP1):
Jumper Name
Jumper Positions
485/422
485
(Default)
422
RTS/AUTO
RTS
AUTO
(Default)
RS-422/485 Multiport Serial PCI Card
422
AUTO
NO_ECHO
NO_LOOP
Mode and Termination Resistor
Setting
2-wire RS-485 mode
4-wire RS-422 mode
RS-485 Transmitter Buffer Enable is
Controlled by RTS (active high)
RS-485 Transmitter Buffer is
controlled automatically by ATTA
hardware circuit
7
RS-422/485 Multiport Serial PCI Card
6.
Set RS-485 in 2-wire (Half Duplex)
Mode
To enable your card to work in the RS-485 2-wire mode, please
follow the following steps:
1. Set the Mode Jumpers (JP1) to "485" and "AUTO" as
mentioned in the above sections.
2. Proceed with the following settings in Windows
Right click on 〝My Computer〞 and choose 〝properties〞
(Win98,ME) or 〝Manage〞(Win2000,XP)
Choose 〝 Device Manager 〞 and double click 〝 Ports 〞 .
You will see the 〝PCI Communications Port(COM3、
COM4) 〞provided by your card.
Double click on 〝PCI Communications Port (COM3) 〞
or 〝PCI Communications Port (COM4)〞then select
〝 Settings 〞
TM
12

Advertisement

Table of Contents
loading

Table of Contents