Starting Self-Diagnostic Function
Press the "MAIN ZONE ON/OFF" (RX-V663 / HTR-
6160: U, F models) / "STANDBY/ON" (HTR-6160: C
model / DSP-AX763) key while simultaneously press-
ing those two keys of this unit as indicated in the figure
below.
Keys of this unit / 本機キー
RX-V663 / HTR-6160 (U, F models)
HTR-6160 (C model) /
DSP-AX763
Starting Self-Diagnostic Function in
the protection cancel mode
If the protection function works and causes hindrance
to trouble diagnosis, cancel the protection function as
described below, and it will be possible to enter the
self-diagnostic function mode. (The protection func-
tions other than the excess current detect function will
be disabled.)
Press the "MAIN ZONE ON/OFF" (RX-V663 / HTR-
6160: U, F models) / "STANDBY/ON" (HTR-6160: C
model / DSP-AX763) key while simultaneously press-
ing those two keys indicated in the figure above. At
this time, keep pressing those two keys for 3 seconds
or longer.
In this mode, the [SLEEP] segment of the FL display
of this unit flashes to indicate that the mode is self-
diagnostic function mode with the protection functions
disabled.
CAUTION!
Using this product with the protection function dis-
abled may cause damage to this unit. Use special
care for this point when using this mode.
36
● ダイアグの起動
本機の下図に示すキーを同時に押しながら "STANDBY/
ON" キーを押すと、ダイアグが起動します。
Turn on the power while pressing these keys. /
これらのキーを同時に押しながら、電源オンする。
● プロテクション解除モードでの起動
プロテクションが動作することにより、故障箇所の診
断に支障をきたすような場合は、次の方法によりプロ
テクションを解除した状態でダイアグモードに入るこ
とができます。 (過電流検出以外のプロテクション動
作を解除する)
上図のキーを同時に押しながら "STANDBY/ON" キー
を押します。このとき、上図のキーを3秒以上押し続
けてください。
このモードでは本機FLの 「SLEEP」 セグメントが点滅
し、プロテクションを解除した状態でのダイアグモー
ドであることを知らせます。
注意!
プロテクション解除モードでの起動は、危険な状態でも
プロテクションが作動しないため、動作させると本機を
破壊することがあります。
このモードを使用する場合は十分注意してください。
Canceling Self-Diagnostic Function
1. Before canceling self-diagnostic function, execute
setting for FACTORY PRESET of main menu No.
23 (Memory initialization inhibited or Memory ini-
tialized).
* In order to keep the user memory stored, be
sure to select PRESET INHIBITED (Memory ini-
tialization inhibited).
2. Turn off the power by pressing the "MAIN ZONE
ON/OFF" (RX-V663 / HTR-6160: U, F models) /
"STANDBY/ON" (HTR-6160: C model / DSP-
AX763: B, J models) key of this unit.
Display provided when Self-Diagnos-
tic Function started
On the FL display of this unit, an opening message
(including the version and the protection history) ap-
pears for a few seconds followed by the main menu
display (1. ANALOG BYPASS).
When there is no history of protection function:
Opening message / オープニング表示
When there is no protection history
プロテクション履歴が無い場合
After a few seconds / 数秒後
NO PROTECT
● ダイアグの解除
1. ダイアグを解除する前に、ダイアグメニューNo. 23
FACTORY PRESET (メモリーの初期化禁止/また
はメモリーの初期化) の設定をします。
※ ユーザーメモリーを保持したい場合は、必ず
PRESET INHIBITED (メモリー初期化禁止) を選
択してください。
2. 本機の "STANDBY/ON" キーを押し、電源オフしま
す。
● ダイアグ起動時の表示
本機のFLディスプレイには、オープニング (プロテク
ション履歴/バージョン) が表示され、数秒後にメイ
ンメニュー表示 (1. ANALOG BYPASS) となります。
プロテクション履歴が無い場合:
Main menu display / メインメニュー表示
1.ANALOG BYPAS