Page 1
THE FEATURE OF PRODUCT Easier Installation : Slim Size Easier Tuning : Using Phase Control Motor DH140EAMC DH105EAMC Various useful Functions Convenient Control Functions UH140GAMC UH105EAMC/UH105GAMC For more information, Please access to our service web site (http://itself.sec.samsung.co.kr)
Contents 11. Precautions ..................................................1-1 Installing the air conditioner ....................1-2 Power supply and circuit breaker ..........................1-3 During operation ........................1-4 Disposing of the unit ..............................1-5 Others 12. Product Specifications ............................................... 2-1 The Feature of Product ...........................
Page 3
Contents 19. Circuit Descriptions ..............................................9-1 PCB Circuit Descriptions ....................... 9-2 Refrigerating Cycle Diagram 10. PCB Diagram ......................................................10-1 Indoor Unit 10-1 ..........................10-2 Outdoor Unit 10-3 11. Operating Instruction and Installation 11-1 ..............11-1 Main Function 11-1 ..........................
If this happens, turn off the air conditioner and contact an authorized service center. Do not spray any kind of liquid into the indoor unit. If this happens, turn off the air conditioner and contact a service center. Samsung Electronics...
G Young children or infirm persons should be always supervised when they use the air conditioner. G Max current is measured according to IEC standard for safety. G Current is measured according to ISO standard for energy efficiency. Samsung Electronics...
– Long piping – • Maximum length : 50m – • Maximum height : 30m I Convenient Control Functions – Auto Change Over – Central Controller(Optional) : Can Control up to 16 units individually – Group Control – Weekly program(Optional) Samsung Electronics...
DH105EAMC DH140EAMC Name Description Number Liquid pipe connection ø9.52 Flare Gas pipe connection ø19.05 Flare Drain pipe connection OD32 ID26 Drain pipe connection Using drain pump (Optional) Power supply connection Air discharge flange Air filter Hook For M8~M10 Samsung Electronics...
Page 8
Production Specifications 2-2-2 Outdoor Unit (Unit : mm) (Unit : mm) (1) UH105EAMC/UH105GAMC Air Inlet(Rear) Air Outlet Connection Valve (Unit : mm) (2) UH140GAMC 4- 12 Air Inlet(Rear) Air Outlet Connection Valve Samsung Electronics...
Outdoor Unit 115.0kg 136.0kg Indoor Unit 320 x 460 x 1150mm 360 x 650 x 1200mm Outer Dimension Outdoor Unit 880 x 931 x 320mm 932 x 1128 x 375mm Indoor Unit 48dB↓ 51dB↓ Noise Outdoor Unit 66/65dB↓ 67dB↓ Samsung Electronics...
• If you input the inappropriate option code, error may occur or the air conditioner is out of order. The option code must be inputted correctly by the installation specialist or service agent. Option items Remote Control SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 Model DH140EAMC DH105EAMC Samsung Electronics...
✳ Setting is not required if you must Push the button to set the display panel to a value which has a default. Every time you push the button, the display panel reads . . . repeatedly. Samsung Electronics...
Page 15
If all lamps of indoor unit are flickering, Plug out, plug in power plug again and press ON/OFF key to retry. If the unit is not working properly or all lamps are continuously flickering after setting the option code, see if the correct option code is set up for its model. Samsung Electronics...
Blower & Motor screws, detach Ass'y Cabi Bottom Blower. 2) Detach from Ass'y Control In the capacitor connection wire between the Motor Fan and housing connector. 3) After disassembling 2 places indicating screws, detach the 2 Fan Case. Samsung Electronics...
Page 17
Remark 4) After disassembling 2 places indicating screws, detach Fan Motor and Blower from the set. 1) After disassembling 1 Indicating screw, Control In detach the Cover control. 2) Detach the Motor-Fan and Sensor Connector from the PCB. Samsung Electronics...
Page 18
Parts Procedure Remark 3) Disassemble 4 indicating screws and detach Control In from the set. Work is possible when Disassembling the Drain Pan Ass'y Cabi Bottom Blower. 1) Disassemble 7 indicating screws and detach Ass'y Cabi Bottom Drain. Samsung Electronics...
Page 19
Holder Pipe. 3) Disassemble 4 indicating screws and detach the Drain Pan. (2 screws each at left and right side) Evap Work is possible when Disassembling the Ass'y Drain Pan. 1) Disassemble 5 indicating screws to detach Cover Pipe. Samsung Electronics...
Page 20
Parts Procedure Remark 2) Disassemble Sensor on the Evap. 3) Disassemble 4 indicating screws which are in the near of Hanger Plate to detach the Evap. (2 screws each at left and right side) It needs 2 peoples. Samsung Electronics...
Page 21
Blower & Motor screws, detach Ass'y Cabi Bottom Blower. 2) Detach from Ass'y Control In the capacitor connection wire between the Motor Fan and housing connector. 3) After disassembling 4 places indicating screws, detach the 2 Fan Case. Samsung Electronics...
Page 22
Remark 4) After disassembling 2 places indicating screws, detach Fan Motor and Blower from the set. 1) After disassembling 1 Indicating screw, Control In detach the Cover control. 2) Detach the Motor-Fan and Sensor Connector from the PCB. Samsung Electronics...
Page 23
Procedure Remark 3) Disassemble 4 indicating screws and detach Control In from the set. ✳ Work is possible when Disassembling the Drain Pan Ass'y Cabi Bottom Blower. 1) Disassemble 6 indicating screws and detach Ass'y Cabi Bottom Drain. Samsung Electronics...
Page 24
3) Disassemble 6 indicating screws and detach the Drain Pan. (3 screws each at left and right side) ✳ Work is possible when Disassembling Evap the Ass'y Drain Pan. 1) Disassemble 5 indicating screws to detach Cover Pipe. Samsung Electronics...
Page 25
Procedure Remark 2) Disassemble Sensor on the Evap. 3) Disassemble 2 indicating screws which are in the near of Hanger Plate to detach the Evap. (1 screw each at left and right side) It needs 2 peoples. 4-10 Samsung Electronics...
6) Disassemble the Cabinet Front. Check if each part is fixed to the electric connector firmly at the time of part assembly. Fan Motor 1) Loosen the Propeller Fan Bolt. 2) Disassemble the Fan. & Propeller Fan Samsung Electronics 4-11...
Page 27
1) Loosen the 8 screws fixing the Cover Control Box Side. & 2) Loosen the screws and push the Cover Side in the arrow direction for disassembly. 3) Disconnect the PCB connector and disassembly the Electronic Box and PCB. 4-12 Samsung Electronics...
5. Exploded Views and Parts List 5-1 Indoor Unit DH105EAMC Samsung Electronics...
Page 30
ASSY-BAND MOTOR HP,NO,SLIM DUCT 3,SSEC 14-5 DB61-02333A CASE BLOWER-BOTTOM EH140EZMC,ABS,T2.0 14-6 DB61-02332A CASE BLOWER-UPPER EH140EZMC,ABS,T2.0 14-7 DB67-00583B BLOWER-D EH140EZMC,ABS YSK140-200-4 DC42GTVA,0.71/ 14-8 DB31-00355B MOTOR FAN 1.4A,50HZ,220V/1.4A HP,T,48K,R22,DH105EAMC DB93-04534A ASSY CONTROL IN PARTS SSEC 15-1 DB90-01992A ASSY CASE-CONTROL 60K,MIDDLE EAST 15-2 DB61-02287A CASE PCB MH020FDEZ,ABS V0,T2.5...
Page 31
Exploded Views and Parts List Indoor Unit (DH140EAMC) 17-9 17-6 17-10 17-8 17-1 17-3 17-4 17-5 17-2 17-7 18-3 18-2 18-9 18-6 18-5 18-1 18-4 18-7 18-8 Samsung Electronics...
Indoor Fan Part(TAP) Heater Discharge Temperature Indoor Fan Part(SSR) External Control Part Display Part EEV Control Part 485 Communication Part Wired Remote Controller Part Address S/W & Option S/W (12V) This Document can not be used without Samsung's authorization. Samsung Electronics...
Page 61
UH140/105GAMC t i n - i n t a c n o i i r o o i t...
Page 62
- 9 1 UH105EAMC l o r t r a l o r t r a , V . t r a l o r t r a i t t i r o o i t Samsung Electronics...
Amount of refilling per extension length of 1mm; when extending the pipe length by more than 7.5m, "A" g of R410 , refrigerant should be refilled per extension length of 1m. Model "A" g UH140GAMC UH105GAMC UH105EAMC Samsung Electronics...
Temperature Sensor Ventilator Wired Remote Controller Power Drain Pump “ External Control(S/W Part) Hot Coil & ‘ Indoor Fan(SSR) Display Power External Control(Display Part) Transformer Out HALL IC Main Power In MICOM Download Power Indoor/Outdoor Communication Transformer In Samsung Electronics 10-1...
Page 65
Display : SMW200-11(WHT) : SMW200-11(WHT) Power : YW396-03AV(WHT) External Control(Display Part) : SMW250-04(RED) Transformer Out : YW396-03AV(WHT) HALL IC : SMW250-03(BLU) Main Power In : YW396-03AV(BLU) MICOM Download : SMW200-10(WHT) Power : YW396-03AV(BLU) Indoor/Outdoor Communication : YW396-02(RED) Transformer In : SMW250-03(RED) 10-2 Samsung Electronics...
Main Power In Transmitter Power(12V) Outdoor Fan 1 Discharge Temperature Sensor Outdoor Fan 2 Outdoor Temperature Sensor Compressor Output Outdoor Pipe Temperature Sensor 4-Way Valve Output Low Pressure S/W Bypass Communication Transformer In Transformer Out 3 Phase Check Samsung Electronics 10-3...
3. To adjust the temperature, press the buttons one or more times until the required temperature is displayed. Possible temperatures are between 18˚C and 30˚C inclusive. 11-1 Samsung Electronics...
Page 70
Possible temperatures are between 16˚C and 30˚C inclusive. 4. Select the fan speed by pressing the button one or more times until the intended value is displayed : ➔ ➔ Automatic(rotated : Medium High Samsung Electronics 11-2...
2. To select the FAN mode, press the button until is displayed at the top of the wired remote controller. 3. Select the fan speed by pressing the button one or more times until the intended value is displayed: Medium High 11-3 Samsung Electronics...
I External Control • You must adjust the K11 when you use external control. Switch No. Switch ON Switch OFF No use of external control Use of external control K 1 K 2 K 3 K 4 SW07 Samsung Electronics 11-4...
Page 73
Connector No. Function PIN #1 and #2 of CN81(RED) +12V Out if any error occurs PIN #3 and #4 of CN81(RED) +12V Out when the compressor is operating Error Display Comp. Status Display Sub. PCB 220V CN81(RED) 11-5 Samsung Electronics...
Filter Sign indicator when the time to clean the air filter. • Duct type air conditioner does not have function of adjusting air flow direction. Therefore, the function is not operated even if you press the button. Samsung Electronics 11-6...
Counts of Indoor 10 11 12 13 14 15 Unit Installation Numbers of the switch G Example : When the installed indoor unit is one, control the arrow of switch forward to ‘0’ or ‘1’ as figure. 12-1 Samsung Electronics...
Adding refrigerant at Adding refrigerant at Displays data Reset heating mode cooling mode Test operation at Test operation at heating mode cooling mode Pump Down for recovery of refrigerant ✳ Use the K1 only for heat pump models. Samsung Electronics 12-2...
Page 77
Wired remote controller Error of communication between the indoor unit and the wired errors remote controller Master wired remote controller ↔ Slave wired remote controller COM1/COM2 Cross-installed error Error of setting option for wired remote controller COM2 12-3 Samsung Electronics...
5. Error of reverse phase 6. Compressor down due to 6'th detection of freezing Detection of the float switch Error of setting option switches for optional accessories EEPROM error EEPROM option error : On : Flickering : Off Samsung Electronics 12-4...
Page 79
The order of priority : E1 → E2 → E3 → E5 → P0 → P1 → P4 → P5 → P9 → t1 → t2 → t3 → tu → to → G4 → G5 → E3 → qx → rx → vx → K1, K2, K3, K4, K5 The order of priority : - In case that the same error displays from multi-indoor units, the one having the faster address has the priority. 12-5 Samsung Electronics...
K4 3 times. At this time, is occurred the difference between the out temp. and data? PCB and sensor are normal. To perform the test operation by use of K2 Reoperation after PCB replacement Samsung Electronics 12-6...
Page 81
K4 2 times. At this time, is occurred the difference between the out temp. and data? PCB and sensor are normal. To perform the test operation by one of K2 Reoperation after PCB replacement 12-7 Samsung Electronics...
Page 82
K4 1 times. At this time, is occurred the difference between the out temp. and data? PCB and sensor are normal. To perform the test operation by use of K2 Reoperation after PCB replacement Samsung Electronics 12-8...
Page 83
PCB, and find the indoor unit preventing communication through connecting the communication connectors each by each, and then replace the indoor unit PCB after line check. Good +0.7V -0.7V 12-9 Samsung Electronics...
Page 84
PCB after line check Samsung Electronics 12-10...
Page 85
PCB about AC220V? Does the water level decrease? Replace the drain pump Replace the indoor unit PCB Normal operation Replace the drain pump Note : E3 error should be released when indoor unit power is reset. 12-11 Samsung Electronics...
4-Way Valve Pipe Temperature Sensor Control part MICOM Sensor Control Part Bypass Valve Outdoor Load 3 Phase 3 Phase Input Control Part Check part Power Supply Communication Room/Pipe/Discharge Part Part 1 Temperature Sensor Indoor Communication Central Control Samsung Electronics 13-1...
It occurs when the drain pump is plugged out or it is out of order. Check the power of the drain pump and the position of the drain hose, and when the pump is faulty, contact the drain pump manufacturer. Samsung Electronics do not manufacture drain pumps. So, we are not able to correct the drain pump problems.
Page 90
Set up a sun blind over the outdoor unit and clear the neighboring obstacles from the outdoor unit to provide good ventilation. When it goes off frequently during a heat wave, it would prevent the turn-off and increase the cooling capacity cleaning the outdoor unit or spraying some water to the heat exchanger. Samsung Electronics 14-4...
Page 91
There is a cost table. But, our service engineer needs to visit to total up the cost correctly. When you move in, make sure to contact Samsung Electronics Service Center or Authorized Service Agent in advance to streamline the process.
5. When you have finished, insert the filter into the unit. 6. Clean the outdoor unit with a vacuum cleaner or a brush once a month. Note : • After cleaning the air conditioner, press the Filter Reset button. Wireless Remote Controller Wired Remote Controller Samsung Electronics 14-6...
Electric and earth work shall meet the "Electric Facility Technology Standard" and the "Internal Wire Regulation" of the Electric Business Laws. I Inspection & Trial Run Upon completion of the tests, you shall make a trial run while you explain the main functions of the air conditioner to finish the installation. 14-7 Samsung Electronics...
183kgf . cm with a torque wrench. A(gas) 7) Check for gas leakage. B(liquid) - At this time, especially check for gas Valve stem leakage from the 3-Way valve’s stem nuts, Stem cap and from the service port cap. Samsung Electronics 14-8...
At this time, cover the valve of the outdoor unit and the other pipe using a cap or vinyl plug to avoid foreign material entering. • Make sure you do not bend the connection pipes in the middle and store together with the cables. • Move the indoor and outdoor units to a new location. 14-9 Samsung Electronics...