Refrigerating Cycle Diagram - Samsung DC42GTVA Service Manual

Table of Contents

Advertisement

9-2 Refrigerating Cycle Diagram

Indoor Unit
Heat
Exchanger
(Evaporator)
Cooling
Gas leak check point
Amount of refilling per extension length of 1mm; when extending the pipe length by more
than 7.5m, "A" g of R410 , refrigerant should be refilled per extension length of 1m.
Model
UH140GAMC
UH105GAMC
UH105EAMC
9-4
Allowable pipe length : Max. 50m
Allowable drop distance : Max. 30m
3-Way valve
Liquid pipe
Gas pipe
3-Way valve
"A" g
70g
70g
70g
Outdoor Unit
Filter
Expansion
valve
Accumulator
Compressor
Filter
Heat
Exchanger
(Condenser)
Muffle
Samsung Electronics

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dc48gtvaUh105gamcDh105eamcUh105eamcDh140eamcUh140gamc

Table of Contents