Don't open your door to the unknown “X” & “S” Series A202CR & A204CR Audio / Video (Day/Night Camera) Audio Audio (Stainless Steel) Installation & Programming 6A-7500 Martin Grove Rd. Woodbridge, ON. Canada L4L 8S9 Toll Free: 1.888.790.5900 E-mail: info@logenex.com...
(Results and features may vary with your local service provider / supplier). 5) If a Logenex DSL 3-Port High-Speed Filter (LX-DSL3F) is installed and the user places a phone caller ON-HOLD using the command to communicate to a Visitor at the Door Station, a low level cross-talk may be heard by the user when communicating to the Visitor at Door Station.
MAY CAUSE DAMAGE TO TELEPHONE EQUIPMEN T. IF YOUR TELEPHONE SYSTEM DOES NOT MEET THE ABOVE REQUIREMENTS PLEASE CONTACT LOGENEX INNOVATIONS INC. FOR FURTHER INFORMATION. SAFETY INSTRUCTIONS When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1.
Features and Parts Listings D.O.C. NOTICE: The Canadian Department of Communications label identifies certified equipment. The certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user’s satisfaction. Before installing this equipment, user should ensure that it is permissible to connect to the facilities of the local telecommunications company.
Controller Anatomy Fig 1 A202CR & A204CR Power Plug Spk/Rly#4 Spk/Rly#3 Spk/Rly#2 Spk/Rly#1 Tele Line In & Out [1] Power Supply Jack This jack is the connecting point for AC power supply to the unit. The supply is typically 16 VAC at a minimum of 250 [2] Power Status LED When "FLASHING"...
“X” Audio & Video Installation Installation Fig 3 Fig 2 (Side View) Fig 2.1 (Side View) 1) Separate back housing from front housing. Step 1 Remove Mounting Holes Post set screw Step 2: swing bottom of housing out. Step 3: pull back Mounting Mounting housing out from top hinge.
“S” Series Audio & Video Installation Installation Fig 4 Audio Connection Fig 2 (Side view) Fig 2.1 (Side view) 1) Separate back Fig 3 housing from front housing. Step Step Step 1: swing top of housing out. Step 2: pull unit out of back Fig 2 (Side View) box.
Controller Wiring Diagram TeleDoorBell Figure 5 A202CR & A204CR 16V AC Output Power Plug Spk/Rly#4 Spk/Rly#3 Spk/Rly#2 Spk/Rly#1 Tele Line In & Out Grey RJ31X (CA38A) Data Jack Green Brown Yellow Black Green Phone RJ31X Black (CA38A) Relay #1 Yellow...
DSL filters at every phone jack High-Speed Internet Modem (supplied by internet provider) A202CR & A204CR PHONE SYSTEM STRUCTURAL PANEL Note: This (DSL 3-PORT FILTER) may cause a LOW- LEVEL AUDIO CROSS-TALK to occur.
VOLTS RMS @ 20 Hz RING. IF INSTALLED WITHOUT VERIFICATION , THIS PRODUCT MAY CAUSE DAMAGE TO TELEPHONE EQUIPMEN T. IF YOUR TELEPHONE SYSTEM DOES NOT MEET THE ABOVE REQUIREMENTS PLEASE CONTACT LOGENEX INNOVATIONS INC. FOR FURTHER INFORMATION. Page 11...
Programming Guide Pick up phone handset and listen for dial tone. *#0 (Listen for (2) Beeps) PRESS to go into programming mode MUST BE ENTERED WITHIN 5 SECONDS OF GOING OFFHOOK ENTER passcode 1111 (Default Passcode) (Listen for (2) Beeps) NOTE: When Entering any programming functions, you have up to 30 seconds idle time before the system will hang up at which point any programming started will not be saved Ring Pattern Configuration...
Page 16
Programming Guide Programming System Features [continued] Continued Multi-Relay Trigger Configuration This feature allows multiple (2) relays to be triggered upon a door button press. 1) PRESS 2) Listen for one (1) BEEP 3) Enter Door Station number. Listen for one (1) BEEP 5) Enter relays to be trigger upon button press.
Page 17
Programming Guide Programming System Features [continued] Continued Programming the Door Station Call Forwarding Phone# This feature allows you to activate the Door Station Call Forwarding feature. When the Door Station Speaker Button is pressed and the call is not answered from one of the premise phone(s) within a specific time limit, the TeleDoorBell will then pick-up the phone line and dial the pre-programmed call forwarding number and if answered, allows the user to communicate to the Door Station Speaker remotely and perform all the functions as though they were within the premises.
Page 18
Programming Guide Programming System Features [continued] Continued Changing the 4-Digit PASSCODE 1111 This feature allows the user to change their 4-Digit PASSCODE. (FACTORY DEFAULT 1) PRESS Listen for (1) BEEP. ____ 3) ENTER NEW (4 DIGIT) CODE (If a new 4 Digit code is not entered within 10 seconds then the previous programmed code will remain) 2) Beeps 4) Listen for for acceptance of programming.
HI-FI Series User/Programming Guide Hi-Fi Feature Operations TeleDoorBell On a door station call the will mute for 1 minute. If the call is answered, the system will remain muted for the duration of the call. The TeleDoorBell will un-mute once communication has ended. TeleDoorBell On an incoming call the will mute on the first ring.
TroubleShooting Please check these items before calling for support. Solution Problem Problem Solution Controller does not power up. 1)Check your AC voltage and power adapter, confirm LED light is flashing. 2)Check power connection into the unit. 1)The unit may have locked up, unplug the power Controller powers up but red LED does not flash, adapter and reconnect after 10 seconds.
Page 21
TroubleShooting Please check these items before calling for support. Solution Problem Problem Problem Solution Solution 1)The line you are connected on may have high Communication is very low when talking to the speed DSL internet on it. This will create door station.
Page 1 of 2 Limited Warranty Logenex Innovations Inc. warrants the original purchaser that for a period of one (1) year from the date of purchase, the product shall be free of defects in materials and workmanship under normal use.
Page 23
Return Number (RMA). Products which Logenex Innovations Inc. determines to be repairable will be repaired and returned. A set fee which Logenex Innovations Inc. has predetermined and which may be revised from time to time, will be charged for each unit repaired.
Page 24