JLG T500J Operation And Safety Manual page 48

Table of Contents

Advertisement

SECTION 4 - MACHINE CONTROLS AND INDICATORS
ONLY USE THE PLATFORM LEVELING OVERRIDE FUNCTION FOR SLIGHT LEVELING OF
THE PLATFORM. INCORRECT USE COULD CAUSE THE LOAD/OCCUPANT TO SHIFT OR
FALL. FAILURE TO DO SO COULD RESULT IN DEATH OR SERIOUS INJURY.
7. Platform Leveling Override
A three position switch allows the operator to adjust the
automatic self leveling system. This switch is used to adjust
platform level in situations such as ascending/descending a
grade.
8. System Distress Indicator
The light indicates that the JLG Control System has detected
a malfunction and a Diagnostic Trouble Code has been set in
the system memory. Refer to the Service Manual for instruc-
tions concerning the trouble codes and trouble code
retrieval.
The malfunction indicator light will illuminate for 2-3 sec-
onds when the key is positioned to the on position to act as
a self test.
4-4
9. Outrigger Indicators
Each individual outrigger indicator will illuminate to show
its' respective outrigger is properly deployed.
10. Outrigger Control
Allows the operator to raise or lower the outriggers.
11. Swing Control
Provides 410° non-continuous turntable rotation.
12. Function Enable.
The switch must be held to the right to enable all
boom controls.
– JLG Lift –