Fuel Filter Cup Cleaning - ACDelco AC-G0005 Instruction Manual

6500 surge watts / 6000 running watts electric start portable generator
Table of Contents

Advertisement

6. Soak the dry sponge-like elements in engine oil. Squeeze out any excess oil. The engine will smoke during initial startup if too much oil is left in
the air filter.
7. Replace the sponge-like elements in the air filter casing (the fine element first) and replace the cover.
Figure 14 - Removing the Air Filter Casing.

Fuel Filter Cup Cleaning

The fuel filter cup is a small well underneath the fuel valve which helps trap dirt and water that may be in the fuel tank before entering the engine.
To clean the fuel filter cup:
1. Turn the fuel valve to the "off" position.
2. Unscrew the fuel filter cup from the fuel valve using a wrench. (Turn the valve toward you to unscrew as illustrated in Figure 15.)
3. Using a rag or brush, clean the cup of all sediment.
4. Reinstall the fuel filter cup.
Figure 15 - Removing the Fuel Filter Cup
22
Model AC-G0005 6500 Surge Watts / 6000 Running Watts Electric Start Portable Generator

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents