Error Code Number Not Previously Described
Error During Function Change
Control Sensor or PCB Relay
1. Turn Digital Mixer off for 15 seconds. Turn back on and allow
15 seconds to reset.
2. If shower operation does not return to normal, replace
Thermistor. (To be performed by competent tradesperson
only!)
3. If shower operation does not return to normal, replace PCB.
(To be performed by competent tradesperson only!)
4. If problem still occurs, make a note of the error code and
contact our Customer Services Team.
Digital Mixer Temperature Motor
1. Turn Digital Mixer off for 15 seconds. Turn back on and allow
15 seconds to reset.
2. If shower operation does not return to normal, check and,
if necessary, replace Mixer Valve. (To be performed by
competent tradesperson only!)
3. If problem still occurs, make a note of the error code and
contact our Customer Services Team.
Digital Mixer PCB Error.
1. Turn Digital Mixer off for 15 seconds. Turn back on and allow
15 seconds to reset.
2. If problem still occurs, make a note of the error code and
contact our Customer Services Team.
Replace batteries.
Control out of range.
Displayed if there is a signal loss between the Wireless Control
Unit and the Digital Mixer whilst a function setting is being
altered. Press " " to clear the display and retry the function
change.