Download Print this page
Vent-Axia CSH12 Installation & Operating Instructions

Vent-Axia CSH12 Installation & Operating Instructions

Combined storage and convector heater

Advertisement

Quick Links

COMBINED STORAGE AND
CONVECTOR HEATER
MODELS:
1.7kW/12kWh Storage and 1kW Convector (CSH12 & CSH12A)
2.55kW/18kWh Storage and 1.5kW Convector (CSH18 & CSH18A)
3.4kW/24kWh Storage and 2kW Convector (CSH24 & CSH24A)
INSTALLATION & OPERATING
INSTRUCTIONS
IMPORTANT
PLEASE READ THIS LEAFLET CAREFULLY
AND RETAIN FOR FURTHER USE
NOTE ALSO THE INFORMATION
GIVEN ON THE HEATER
The Installation must be carried out by trained
personnel.
A means for disconnection must be
incorporated in the fi xed wiring by a double pole
switch with a contact separation of a minimum
of 3mm and in accordance with the current IEE
Wiring Regulations.
The heater must not be installed immediately
below a fi xed socket outlet.
The heater is not suitable for connection to a
30A ring circuit.
Do not position the heater under windows where
curtains can contact the heater casing.
WARNING - THE SURFACES ON THIS HEATER CAN BE HOT.
This heater meets EN60335 safety requirements. However, any heater type becomes hot in normal operation.
Care must be taken to ensure that prolonged skin contact with the heater does not occur.
WHERE YOUNG CHILDREN, INFIRM PERSONS, OR THE AGED ARE PRESENT THIS APPLIANCE MUST
BE ADEQUATELY GUARDED. Contact your installer or the manufacturer for further advice.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental
capabilities, or lack of experience and knowledge, unless they have been given supervision for instruction
concerning use of the appliance by a person responsible for their safety. Children should be supervised to
ensure that they do not play with the appliance.
This appliance is very heavy and must be securely fi xed to a wall. DO NOT UNDER ANY CIRCUMSTANCES
ATTEMPT TO MOVE OR REPOSITION THIS HEATER WITHOUT SEEKING EXPERT ADVICE.
To maintain stability, it is essential that the heater is placed on a level surface.
This heater must be installed where it is impossible for switches and other controls to be touched by a person
using a bath or shower.
IMPORTANT - Due to the newness of materials the heater will produce a slight smell for the fi rst few days of
operation. ROOMS MUST BE WELL VENTILATED AND YOUNG CHILDREN, CAGED BIRDS, OR PERSONS
WITH RESPIRATORY COMPLAINTS MUST NOT REMAIN IN CLOSE PROXIMITY TO THE HEATER DURING
THE FIRST 48 HOURS OF THE COMMISSIONING PERIOD.
IF, DURING ANY REASSEMBLY OF THE HEATER, A PART OF THE THERMAL INSULATION SHOWS
DAMAGE OR DETERIORATION WHICH MAY IMPAIR SAFETY, IT SHOULD BE REPLACED BY AN IDENTICAL
PART.

Advertisement

loading

Summary of Contents for Vent-Axia CSH12

  • Page 1 COMBINED STORAGE AND CONVECTOR HEATER MODELS: 1.7kW/12kWh Storage and 1kW Convector (CSH12 & CSH12A) 2.55kW/18kWh Storage and 1.5kW Convector (CSH18 & CSH18A) 3.4kW/24kWh Storage and 2kW Convector (CSH24 & CSH24A) INSTALLATION & OPERATING INSTRUCTIONS IMPORTANT PLEASE READ THIS LEAFLET CAREFULLY...
  • Page 2 Carefully slide the sensor plate down from its transit position to its operational position. The heater will arrive CSH12 & CSH12A - 8 bricks separately from its CSH18 & CSH18A - 12 bricks storage bricks, the following bricks will CSH24 &...
  • Page 3 Fit the front layer of bricks again with the recess towards the element. The complete core will comprise: 12 - 2 x 4 Brick Columns 18 - 3 x 4 Brick Columns 24 - 4 x 4 Brick Columns Replace the inner front complete with insulation by locating its bottom edge behind the front lip of the chassis and inserting retaining screws along the top and both sides.
  • Page 4: Control Functions

    Please recycle where facilities exist. Check with your For models CSH12, CSH18 and CSH24 only: Local Authority or retailer for recycling advice in your country. Initially set the input to 4. If the heater does not maintain a satisfactory room temperature the following day this setting should be increased.

This manual is also suitable for:

Csh12aCsh18Csh18aCsh24Csh24a