STEPS TO
PROGRAMMING
WARNING These steps involve
working with hot water. Scalding
may occur if care is not taken
against spilling.
ENTERING THE PROGRAM MODE #1
Turn OFF the power from the Control Panel by pressing
Press and HOLD
and press and RELEASE
Continue HOLDING
ENTER THE PROGRAM MODE #2
Turn OFF the power from the Control Panel by pressing
Press and HOLD
and press and RELEASE
Continue HOLDING
until
ENTER THE PROGRAM MODE #3
Turn OFF the power from the Control Panel by pressing
Press and HOLD
and press and RELEASE
Continue HOLDING
until
RELEASE.
2
PROGRAMMING ONLY REQUIRED IF FACTORY SETTINGS MUST BE CHANGED
Changing the ADS™ System Program
IMPORTANT – Before entering the program mode, allow the unit to reach brewing temperature, then press the BREW
button to dispense at least 12 ounces of water. This is to clear any air that may be trapped within the water lines.
NOTE: For ALL functions you must first enter the programming mode.
NOTE:
NOTE:
NOTE:
NOTE:
Brew Temperature – Factory Pre-Set to 200°F
Function to set brew temperature, 170° to 204°F. Brew temperature will be indicated by READY-TO-BREW light blinking.
.
.
until
starts blinking; RELEASE.
READY TO BREW
BREW VOLUME - Factory Preset to Brewer Requirements
BREW CYCLE COUNTER
.
.
STOPS blinking; RELEASE.
READY TO BREW
LOW TEMPERATURE BREW LOCKOUT (DELTA) – Factory Preset to Delta 3
.
.
stops blinking and remains on;
READY TO BREW
CONFIRM/RESET BREW TEMPERATURE - Factory Preset to 200º
ENTER THE PROGRAMMING MODE #1:
Press
for two seconds, then RELEASE.
will start blinking. Each blink equals 2º F, starting at 170º.
READY TO BREW
To change Temperature, press and HOLD
.
will start QUICK flashing. Each QUICK flash equals 2º F.
READY TO BREW
After reaching 204º, temperature starts over at 170º.
RELEASE
when the desired temperature is reached.
To set and exit, press
.
CHANGE BREW VOLUME
ENTER THE PROGRAMMING MODE #1
Press and HOLD
until hot water starts running from sprayhead; then RELEASE.
When desired volume is reached, press
To set and exit, press
.
TO ACCESS BREW CYCLE COUNTER
ENTER THE PROGRAMMING MODE #2:
will now start a pattern of LONG and SHORT blinks.
READY TO BREW
This pattern identifies the number of brew cycles. SHORT blinks indicate the brew number from one [1] to nine [9].
LONG blinks separate the 1's, 10's, 1,000's and 10,000's.
ENTER THE PROGRAMMING MODE #3
This mode will give you a choice of minimum brew temperatures.
Delta 1
Delta 1 allows you to brew within 5 degrees from set temperature. This provides for consistent brew
Delta 1
Delta 1
Delta 1
temperature and consistent water density. If Delta 1 is used, run one half decanter first, cancel and
discard water. Enter program mode #1 and change brew volume to 1/2" below collar of decanter (one
small finger width).
Delta 2
Delta 2
Delta 2
Delta 2
Delta 2 allows you to brew within 15 degrees from set temperature. If Delta 2 is used, run 3/4 of a
decanter first, cancel and discard water. Enter program mode #1 and change brew volume to 3/4"
below collar of decanter (between one and two small finger widths).
Delta 3 (this is factory setting) will allow you to brew at any temperature. Back to back brewing is only
Delta 3
Delta 3
Delta 3
Delta 3
possible in this mode. If Delta 3 is used, run one half decanter first, cancel and discard water.
Enter program mode #1 and change brew volume to 1" below collar of decanter (two small finger
widths). The brew cone must be empty without a filter. This will ensure proper operation at all brew
rates.
Press and HOLD
until
gives off one quic flash, then release
READY TO BREW
your blining light pattern.
By pressing and holding the
again, you add another blink.
.
again to stop flow.
. You have now added a blink to