Test Mode

Start/Pause
___ times
Note: This information was verified on an early production dryer. The sequence of operations may
vary on the particular dryer being serviced.
DLEC733W
To enter the QC Test Mode, press the Power button while holding the
Buzzer and Wrinkle Care buttons. After entering the QC Test Mode, step
through the tests below by pressing the Start/Pause button.
0
LEDs
1
Motor on (CCW), Humidity data
2
Motor on (CW), Humidity data
Motor on (CW)
3
1750W heater on
Motor on (CW)
4
both heating coils on
5
Pump on, Motor off
6
Motor on (CW)
7
Motor off
8
Motor off, Buzzer on
9
End QC Test mode
Checkpoint
Display
Programming checksum
Moisture data (Normal: 230-245)
Moisture data (Normal: 230-245)
Temperature at the low temp
thermistor under the door
Temperature at high temp
thermistor located in heater
Moisture data (Normal: 230-245)
Moisture data (Normal: 230-245).
(For moisture sensor check on production
line by opening door with door switch
pressed.)
Moisture data (Normal: 221) by
semiconductor moisture sensor.
No ELB (Earth Leakage Breaker)
p13