CONFIRMATION OF CHECK SUM, MICON VERSION AND POWER ON TOTAL HOURS.
Initial total of MEMORY IC and REGISTER DATA, MICON VERSION and POWER ON total hours can be checked on the
screen. Total hours are displayed in 16 system of notation.
NOTE:
If you set a factory initialization, the total hours is reset to "0".
Please refer to "CONFIRMATION OF INITIAL DATA" when SUM DATA is not corresponding.
1.
Turn on the POWER.
2.
Set the VOLUME to minimum.
3.
Press both VOL. DOWN button on the set and Channel button (2) on the remote control for more than 2 seconds.
4.
After the confirmation of CHECK SUM, MICON VERSION and POWER ON TOTAL HOURS, turn off the power.

CONFIRMATION OF INITIAL DATA

If a service repair is undertaken where it has been required to change the MEMORY IC, the following steps should be taken to
ensure correct data settings while making reference to INITIAL SETTING TABLE (Attached "INITIAL DATA").
1.
Turn on the POWER, and set to the TV mode.
2.
Set the VOLUME to minimum.
3.
Press both VOL. DOWN button on the set and Channel button (6) on the remote control for more than 2 seconds.
ADDRESS and DATA should appear as FIG 2.
4.
ADDRESS is now selected and should "blink". Using the UP/DOWN buton on the remote, step through the ADDRESS
until required ADDRESS to be changed is reached.
Press RIGHT/LEFT button to select DATA. When DATA is selected, it will "blink".
5.
6.
Again, step through the DATA using UP/DOWN button until required DATA value has been selected.
7.
Pressing RIGHT/LEFT button will take you back to ADDRESS for further selection if necessary.
8.
Repeat steps 4 to 6 until all data has been checked.
9.
When satisfied correct DATA has been entered, turn POWER off (return to STANDBY MODE) to finish DATA input.
After the data input, set to the initializing of shipping.
Turn POWER on.
10.
11.
Press both VOL. DOWN button on the set and Channel button (1) on the remote control for more than 2 seconds.
12.
After the finishing of the initializing of shipping, the unit will turn off automatically.
The unit will now have the correct DATA for the new MEMORY IC.

WHEN REPLACING EEPROM (MEMORY) IC

MICON Version
INIT : 28B9
VCT-P : 7C74
LCD ON : 0000
DB010_70123A
FIG. 1
ADDRESS DATA
INIT 0000 00
LDC ON 0000
DB010_70123A
FIG. 2
C-1
Initial setting data check sum.
Register data check sum.
POWER ON total hours.
= (16 x 16 x 16 x thousands digit value)
+ (16 x 16 x hundreds digit value)
+ (16 x tens digit value)
+ (ones digit value)